3. Resistance Measurement
Range
400.0Ω
4.000kΩ
40.00kΩ
400.0kΩ
4.000MΩ
40.00MΩ
400Ω range: Measured value = (Measured display value) – (Short-circuiting
value of probe)
Open circuit voltage: around 0.5V
Overload protection: 600Vrms
4.
: Continuity
Range
Resolution
0.1Ω
1mV
G
Overload protection: 600Vrms
5. Capacitance Measurement
Range
40.00nF
400.0nF
4.000uF
40.00uF
100.0uF
Overload protection: 600Vrms
Resolution
0.1Ω
10Ω
100Ω
1kΩ
10kΩ
G : Diode measurement
Open circuit voltage is around 0.5V.
Resistance >150Ω, buzzer will not sound.
Resistance ≤10Ω, buzzer will sound.
Open-circuit voltage is around 1.5V. Normal voltage is
around 0.5V to 0.8V for silicon PN junction.
Resolution
10pF
100pF
1nF
10nF
100nF
±(1.2%+2dgt)
±(1.0%+2dgt)
±(1.2%+2dgt)
±(1.5%+5dgt)
Accuracy
±(3%+10dgt) under REL status
±(3%+5dgt) under REL status
±(3%+5dgt)
±(4%+5dgt)
14
Accuracy
Accuracy