PROBLEM
No water is coming out of the faucet
SOLUTION
Check the battery. Low or used up batteries. Replace the battery. See page 57
Check the flow time. See page 51
Verify the connection between the connector of the Piezo lid and the solenoid connector.
Check that the battery box is correctly connected..
Verify the solenoid valve. If there is waste or calcareous sedimentation, loosen the solenoid valve,
remove the piston and the buffer that are inside and clean them. Use an anti-calcareous product if
necessary. When restoring the buffer, make sure that it is in vertical position.
Check the diaphragm. If needed, clean the orifice or replace it.
Verify water pressure. It must be between 0,5 y 4.0 bar. Use a reducing valve for pressure above 4 bar.
PROBLEM
Water flow does not stop
SOLUTION
Check the flow time. If needed adjust it following the instructions at page 51.
Verify the solenoid valve. If there is waste or calcareous sedimentation, loosen the solenoid valve,
remove the piston and the buffer that are inside and clean them. Use an anti-calcareous product if
necessary. When restoring the buffer, make sure that it is in vertical position.
//