„Beep" sound – reaction to operation of pressing a key
Sound parameter enables switching on/off a 'beep' sound responsible for informing a user about
pressing any key of balance overlay.
NO
- 'beep' sound off
YES - 'beep' sound on.
Backlight, and display brightness adjustment
The parameter enables setting the brightness of the backlight or switching off the display brightness
completely.
100
- maximum brightness of the backlight
10
- minimum brightness of the backlight
NONE - display brightness switched off
Backlight turn-off time
Parameter <P6.5 STAND-BY MODE> enables use of function responsible for activation of the
display stand-by mode when weighing process is not being performed (stable indication is a
necessary condition for activation of the stand-by mode).
NONE
0.5; 1; 2; 3; 5 – time given in minutes
If the software registers stable indication for a specified time interval, set in parameter <P6.5 STAND-
BY MODE>, than the display goes out immediately.
The backlight activates upon change of indication (no stability pictogram on the display) or pressing
any key on the balance keypad. Blanking works also when balance menu is entered.
CAUTION:
It is not recommended to run screensaver mode in balances with d=0.01 mg, this is due to
the fact that switching the backlight on/off causes temperature change which may affect the
error of repeatability. In the case of balances with d= 0.01 mg it is advised to set the backlight
parameter to value <None>.
Auto switch-off
Parameter <P6.6 AUTO OFF> enables use of function responsible for automatic display deactivation
(functions as
button). Upon display deactivation the other subassemblies are powered and the
balance turns to stand-by mode.
NONE
0.5; 1; 2; 3; 5 – time given in minutes
If the software registers stable indication for a specified time interval, set in parameter <P6.6 AUTO
OFF> settings, than the display is turned-off immediately (inactive backlight function, no indication on
the display, clock displayed).
To start-up the balance it is necessary to press
balance will automatically return to weighing.
The balance cannot be turned off if any process is started or if balance menu is entered.
Date
Date parameter enables setting the current date.
Procedure:
Time
Date parameter enables setting the current time.
Procedure:
– backlit turn-off time not activated
– auto switch-off not activated
button located on the balance keypad. The