MWE7006
9
Registering and identifying sensors
The sensors and their position must be registered by the control unit. To do this,
proceed as follows:
➤ Switch on the ignition.
➤ Engage the reverse gear.
✓ The control unit registers the sensors connected.
✓ The display on the control unit shows LE.
✓ The loudspeaker emits short acoustic signals repeatedly.
Once the registration is complete, LE flashes on the display. The sensors must now
be identified by the control unit.
➤ Park the vehicle so that it is surrounded by at least 1.5 m of free space to ensure
the sensors cannot detect any obstacles.
➤ Switch the ignition off and on again.
➤ Engage the reverse gear.
➤ Press both buttons on the control unit for more than three seconds.
✓ The control unit registers the sensors connected.
Once the registration is complete, the loudspeaker emits a long acoustic signal. The
sensors must now be identified by the control unit.
The display shows a running light and the loudspeaker emits short acoustic signals
repeatedly.
➤ Proceed as follows in accordance with the installation alternative you selected
(fig. 6):
– Alternative A: Use a large object approx. 0.5 m² in size (e.g. a piece of sturdy
paper) and go to sensors 1 to 6 successively (fig. b A)
– Alternatives B and C: Starting at the driver's door, walk around the vehicle
from the first to the last sensor (fig. b B and C).
✓ The loudspeaker acknowledges each sensor detected with a short acoustic
signal.
Once identification is complete, the loudspeaker emits a long acoustic signal.
I
NOTE
If an error occurs during this procedure, you can restart the procedure
by pressing both buttons together for longer than three seconds.
EN
Registering and identifying sensors
9