schmalz CPi FS RP Notice D'utilisation page 54

Table des Matières

Publicité

IO-Link Data Dictionary
21.10.01.00115/00
IO-Link Implementation
Parameter
Device Settings
Commands
2
0x0002
0
System Command
58
0x003A
0
Teach-In Channel
59
0x003B
0
Teach-In Status
Access Control
Device Access Locks
12
0x000C
0
77
0x004D
0
Pin
Menu PIN code
Initial Settings
Signal Type
73
0x0049
0
P-n
Display Unit
74
0x004A
0
uni
76
0x004C
0
Eco
Eco-Mode
Display Rotation
79
0x004F
0
dIS
J. Schmalz GmbH
5, 65, 130, 165,
1 byte
wo
66, 167, 168, 169
1 byte
1, 2
rw
1 byte
ro
2 bytes
0 - 7
rw
2 bytes
0 - 999
rw
1 byte
0 - 1
rw
1 byte
0 - 3
rw
1 byte
0 - 2
rw
1 byte
0 - 1
rw
3 of 6
0
0
0
0
0
0
SMP FS RP
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
0x05 (dec 5): Force upload of parameter data into the master
0x41 (dec 65): Execute single-value teach for currently selected SPx
0x82 (dec 130): Restore device parameters to factory defaults
0xA5 (dec 165): Calibrate sensor
0xA7 (dec 167): Reset erasable counters ct1 and ct2
0xA8 (dec 168): Reset voltage HI/LO
0xA9 (dec 169): Reset sensor HI/LO
Select switch point 1 or 2 for teaching
Result of last teach-in command:
0x00 = Channel changed
0x07 = Teach-in failed
0x11 = Teach-in successful
Bit 0: Parameter access lock (lock ISDU-write access)
Bit 1: Data storage lock
Bit 2: Local parameterization lock (lock menu editing)
0 = Menu editing unlocked
>0 = Menu editing locked with pin-code
0 = PNP
1 = NPN
0 = mbar
1 = kPa
2 = inHg
3 = psi
0 = off
1 = on (full eco mode with display switching off completely)
2 = Lo (medium eco mode with display dimmed to 50%)
0 = Standard
1 = Rotated
13.03.2018
VSi Data Dictionary

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Scpi fs rp