Simu RSA Hz Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.2- Safety input function: Parameters
- When using a resistive safety edge, the latter must be wired onto safety input 1. The opening safety device (
configurable action).
Configuration of safety input 1 (safety edge*): Parameter
No accessories connected to safety input 1 (default mode)
Accessory connected to safety input 1 enabled when opening the door
Accessory connected to safety input 1 enabled when closing the door
Configuration of safety input 2 (photocell*): Parameter
No accessories connected to safety input 2 (default mode)
Accessory connected to safety input 2 enabled when opening the door
Accessory connected to safety input 2 enabled when closing the door
Configuration of safety input 3: Parameter
No accessories connected to safety input 3 (default mode)
Accessory connected to safety input 3 enabled when opening the door
Accessory connected to safety input 3 enabled when closing the door
4.3- Safety action upon closing: Parameter
- The safety action at opening (
=
) can be configured.
Stop the door
Ensure you configure the safety input used for the appropriate self-test: safety 1: P1+P5, safety 2: P2+P6, safety 3: P3+P7 Once the safety accessories
are connected and the safety inputs configured, check manually the proper operation of the accessories before the final start up of the facility.
4.4- Configuration of the self-testing function: Parameters
- The self-test function is used to check proper operation of the safety accessories automatically at the end of closing.
Self-testing safety input 1: Parameter
No self-test of the accessory connected (default mode)
Self-test for photocells by power supply cutting. Caution : The transmitting cell
must be supplied on terminals 10/12 and the receiver cells on terminals 10/11).
Self-test for accessory fitted with a TEST input (cells or sensor bar).
Self-testing safety input 2: Parameter
No self-test of the accessory connected (default mode)
Self-test for photocells by power supply cutting. Caution : the transmitting cell
must be supplied on terminals 10/12 and the receiver cells on terminals 10/11).
Self-testing safety input 3: Parameter
No self-test of the accessory connected (default mode)
Self-test for photocells by power supply cutting. Caution : the transmitting cell
must be supplied on terminals 10/12 and the receiver cells on terminals 10/11) :
4.5- Programming remote controls : Parameter
- According to the type of operation chosen in chapter 3.1, the value of the
Sequential mode
Select parameter
by pressing several time on the
- For programming the "UP / STOP / DOWN" order, select using the key
- For programming the auxilliary output order, select using the key
3 buttons mode
Select parameter
by pressing several time on the
- For programming the "UP" order, select using the key
- For programming the "DOWN" order, select using the key
- For programming the "STOP" order, select using the key
- For programming the auxilliary output order, select using the key
(factory setting =
(factory setting =
(factory setting =
)
(factory setting =
)
=
) is not configurable (stopage followed with partial door reopening). However, safety actions upon closing (
Stop, then total reopening of the door (default mode)
(factory setting =
)
(factory setting =
)
(factory setting =
)
Opening
Stop
Closing
key From the release of the key, the display indicates
or
Opening
Stop
closing
opening
key From the release of the key, the display indicates
or
the functionality
or
the functionality
or
the functionality
or
)
ADMAP** safety: active upon closing + forbids starting at opening
Contact for connecting an emergency stop device
)
ADMAP** safety: active upon closing + forbids starting at opening
Contact for connecting an emergency stop device
ADMAP** safety: active upon closing + forbids starting at opening
Contact for connecting an emergency stop device
Stop then partial reopening of the door(2 seconds operation)
Self-test for resistive sensor bar (value comprised between 4 and 12 K
Self-test for optical sensor bar
Self-test for accessory fitted with a TEST input (cells or sensor bar).
Self-test for accessory fitted with a TEST input (cells or sensor bar).
parameter does not produce the same effects.
or
the functionality
then program the key associated with this order.
the functionality
then program the key associated with this order.
Auxilliary
closing
Stop
then program the key associated with this order.
then program the key associated with this order.
then program the key associated with this order.
the functionality
then program the key associated with this order.
=
) stops then recloses partially (non
Opening / Closing Command (default mode).
Auxiliary output control (driving the accessory
connected to the AUX output).
and flashes.
Open command
Close command
Stop command
Auxiliary output control (driving the accessory
connected to the AUX output).
and flashes.
3/4

Publicité

Table des Matières
loading

Produits Connexes pour Simu RSA Hz

Table des Matières