9.1.5 Supplementary installation instructions
9.1.5.1 Flue gas exhaust
In case of the Folke the flue can be connected in two ways: drained or non-drained. For this you will have to use
the specially developed conical ring. The required connecting pieces are available through your supplier.
In case of a connection at the rear, please proceed as follows (see Appendix 2, fig. 2):
Ø
Remove the 3 bolts from the exhaust ring mounted at the top of the appliance.
Ø
Remove the bolts from the plate at the rear of the appliance.
Ø
Mount this plate on the top of the appliance, on the location where the exhaust ring used to be.
Ø
Mount the exhaust ring at the rear of the appliance by tightening the 3 bolts.
If a RS appliance is installed, the flue gas discharge must be connected airtight. Do this with heat-resistant sealant.
!Caution
9.1.5.2 Outside air connection
It is possible to provide the Folke with an outside air connection. This outside air connection is optionally available
(as an external kit). This kit can be used for a connection on the bottom of the appliance and is available through
your supplier (see Appendix 2, fig. 4).
If you install a Folke RS appliance, the outside air connection is already pre-mounted on delivery. Observe the
!Caution
steps as described under the heading 'Outside air connection pre-mounted'.
When assembling the outside air connection, proceed as follows:
Outside air connection not pre-mounted (see appendix 2, fig. 13):
Ø
Remove unit 'A' (fig. 13-I) by loosening the 4 screws and removing them.
Ø
Remove the plate (B, fig. 13-I) fixed on the air slide by loosening the 2 screws and removing them.
Ø
Take the 4 pre-assembled screws (fig. 13-I) out of the bottom side of the appliance.
Ø
Place the tray with mounted pipe opening against the bottom of the appliance (fig. 13-II).
Ø
Re-use the 4 screws to mount the tray (fig. 13-II).
Ø
Replace plate (B, fig. 13-III) and tighten it again with the 2 screws.
Ø
Replace unit 'A' (fig. 13-III) and tighten the 4 screws again.
Ø
Connect the flexible hose (Ø 80 mm) to the round pipe opening of the outside air connection. The flexible hose
can be fed both from the back and the bottom. For this purpose, the round plate at the back or bottom of the
appliance must be pressed out (see appendix 2, fig. 4).
For disassembling the outside air connection, please observe the above-mentioned steps in reverse order.
Outside air connection pre-mounted (see appendix 2, fig. 4):
Ø
Connect the flexible hose (Ø 80 mm) to the round pipe opening of the outside air connection.
The Folke is a fully enclosed system. Always ensure an air-tight connection of the flexible hose to the round pipe
Caution!
opening by using a heat resistant sealant.
For disassembling the outside air connection, please observe the above-mentioned steps in reverse order.
9.1.5.3 Coverplate
When with the installation of the Folke you use an outside air connection, a coverplate (see annex 2, figure 14 and
15) is available from your supplier. This coverplate keeps the flexible hose out of sight.
42
I N S T A L LA T I ON M A N U A L