Flame Baffle Plate; Door; Adjusting The Door; Replacing Door Seal - Dik Geurts Folke Instructions D'installation

Masquer les pouces Voir aussi pour Folke:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.1.2.2 Flame baffle plate

On delivery the flame baffle plate (see Appendix 2, fig. 3) is located in the top section of the appliance.
In case of maintenance to the appliance, the flame baffle plate has to be removed.
To do this proceed as follows:
Ø
Take the flame baffle plate.
Ø
Tilt the flame baffle plate forwards so the rear comes upwards.
Ø
Slide the flame baffle plate forwards so the rear of the flame baffle plate is released from the ridge.
Ø
Lower the flame baffle plate and remove it.
Placing the flame baffle plate takes place in reverse order.

9.1.3 Door

Check the closing of the door during installation or maintenance.
To do this proceed as follows:
Ø
Check the sealing of the door by placing a sheet of paper between the door and the fire. After closing the door, it
should not be possible to pull out the sheet of paper easily. Check the outside of the fire.
In case the door still doesn't seal properly:

9.1.3.1 Adjusting the door

You can adjust the door by slightly moving 2 door catches (see Appendix 2, fig. 8). The door catches are found on
the top side and bottom side of the appliance.
Proceed as follows:
Ø
Loosen the 2 bolts on the top side of the appliance a little.
Ø
Adjust the catch.
Ø
Then re-tighten the bolts properly.
Ø
Repeat these steps at the bottom of the appliance.
It may be the case that the door already closes properly after adjusting the top or bottom door catch.So it is not
Tip!
always necessary to adjust both door catches.
Ø
Check whether the sealing tape makes a good connection by clamping a sheet of paper between the stove and
the sealing tape when closing the door.
Ø
It should not be easy to pull out the sheet of paper. If necessary, adjust the door and/or replace the door seal (=
sealing tape, see section 9.3.2). If the door seal is in order or replaced, the process of adjusting the door must be
repeated until the door closes properly.
Ø
After adjusting the door check that cast-iron door handle still matches and closes properly. Adjust the door
handle if this is not the case (see Appendix 2, figure 9).
Ø
Slightly loosen the bolts in the slotted holes and slide the door handle.
Ø
Then re-tighten the bolts properly.

9.1.3.2 Replacing door seal

When replacing the door seal proceed as follows (see Appendix 2, fig. 10):
Ø
Open the door.
Ø
Remove the cord and the mastic from the recess.
Ø
Apply a new layer of heat resistant mastic in the recess where the cord was.
Ø
Place a new cord in the recess. Do this loosely and do not pull the cord tight.
Ø
Insert both ends of the cord in the special sleeve.
The cord, the sleeve and the mastic are available through your supplier.
Make sure that the sleeve is placed on the underside of the glass pane.
!Caution
40
Adjust the door (see section 9.1.3.1) and/or
replace the door seal (see section 9.1.3.2).
I N S T A L LA T I ON M A N U A L

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kalle

Table des Matières