9.2 Interior lining

9.2.1 Vermiculite

The fire's vermiculite plates are located on the bottom and against the rear wall of the appliance
(see Annex 2, fig. 8). In the following situations the vermiculite plates must be taken out:
The bottom plates and the underlying felt are first removed and the rear plates last. The insertion of the
vermiculite plates takes place in reverse order.
Make sure that the vermiculite plates are placed back in the original position! The back plate, for instance, must be
!Caution
placed with the small, not countersunk, holes towards the front.

9.2.2 Flame baffle plate

On delivery the flame baffle plate (see Annex 2, fig. 8) will be lying on the bottom of the appliance.
It must be placed on the accompanying profiles in the top of the appliance.
To do this proceed as follows:
Ø
Take the flame baffle plate and tilt it backwards.
The stainless steel profile must be placed at the front with the screw heads facing the top (see Annex 2, fig. 8).
!Caution
Ø
Lift the flame baffle plate into the top of the appliance.
Ø
Slide the front of the flame baffle plate over the 2 iron supports located at the top, at the front of the appliance
(see Annex 2, fig. 9).
Ø
Then slide the flame baffle plate towards the back and centre it in the appliance.
Ø
The flame baffle plate is now in the correct place.
The removal of the flame baffle plate takes place in reverse order.
40
When disassembling the air slide valve (see section 9.1.2).
To be able to reach the adjustable legs (see section 9.5).
When replacing the vermiculite plates.