PowrPlast 600
malfunctIon
Pressure at the manometer rises
to more than 40 bars.
Mortar spraying machine does
not pump enough coating ma-
terial.
Coating material is emitted at
the inspection hole (1).
If the defect is not caused by one of the above-mentioned faults, have the defect eliminated by the Titan customer service.
possIble cause
Viscosity of the coating material too
high.
Mortar hose diameter too small.
Mortar hose is too long.
Coating material "plug" in the mortar
hose. Mortar hose not prerinsed with
cellulose paste.
Convey capacity selected too low.
Mortar hose diameter too small.
Stator worn.
Texture tip too small.
The shaft seal that seals between the
pump unit and the drive unit is worn.
1
elImInatIon
Dilute the coating material.
Use a mortar hose with a larger diameter.
Use a shorter mortar hose.
Depressurize the mortar hose – set the selector
switch to "R" (reverse).
Pump the coating material back into the con-
tainer.
the mortar hose must be pres-
sureless.
Watch the manometer ––> 0 bar.
Wear safety goggles.
Decouple mortar hose and rinse with water hose.
When the plug has been removed, fill cellulose
paste in the mortar hose. Couple the mortar hose
back on.
Set the volume regulator higher.
Use a mortar hose with a larger diameter.
Mount a new stator, if necessary, also a new rotor.
Attention: Spray on pump sliding means.
Select a larger texture tip.
Rule of thumb: Granular size x 3 ––> Tip size
Stop work immediately because otherwise coat-
ing material may enter the drive and result in a
defect.
Clean machine and contact Titan customer serv-
ice.
GB
elImInatIng faults
49