Protective Measures; Remedy Of Faults - Pontec PondoMax Eco 1500 Notice D'emploi

Masquer les pouces Voir aussi pour PondoMax Eco 1500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Installation
How to proceed:
 A
Cut the stepped hose adapters such that the connection opening coincides with the hose diameter. This helps to avoid
pressure loss.
At the filter pump, push or turn the hose onto the stepped hose connection, secure with hose clips and screw onto the
filter pump connection thread.
Installation
Place the unit in the pond horizontally on firm, sludge-free ground and ensure that it is completely covered with water
at a maximum of 4 m below the surface of the water.
Commissioning/start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.

Remedy of faults

S
Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running time
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Excessive loss in the supply hoses
Excessively soiled water
Water temperature too high
Remedy
Check mains voltage
Clean/check supply lines
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Clean pump
Note maximum water temperature of +35 °C
- EN -
9

Publicité

Table des Matières
loading

Table des Matières