Installation and Operating Instructions
CHAPTER 2
GENERAL INFORMATION
m
DANGER
Centrifugal cooling air fans – B KLG 500/1000
2 .0
Warranty claims – Exclusion of liability
All versions of this documentation must be observed, otherwise the warranty shall cease to apply. The same applies
to liability claims against Helios. The use of accessory parts, which are not recommended or offered by Helios, is not
permitted. Any possible damages are not covered by the warranty. Changes and modifications to the unit are not
permitted and lead to a loss of conformity, and any warranty and liability shall be excluded in this case.
2 .1
Regulations - Guidelines
If the unit is installed correctly and used to its intended purpose, it conforms to all applicable regulations and EU gui-
delines at its date of manufacture.
2 .2
Shipping
The unit is packed ex works in such a way that it is protected against normal transport strain. Carry out the shipping
carefully. It is recommended to leave the unit in the original packaging and secure it with a lashing strap for ship-
ping.
Do not transport centrifugal cooling air fans on connection cables, terminal box or impeller!
2 .3 Receipt
The shipment must be checked for damage and correctness immediately upon delivery. If there is any damage,
promptly report the damage with the assistance of the transport company. If complaints are not made within the agreed
period, any claims could be lost.
2 .4
Storage
When storing for a prolonged time, the following steps are to be taken to avoid damaging influences: Motor protection
by dry, airtight and dust-proof packaging (plastic bag with desiccant and humidity indicators). The storage place must be
water proof, vibration-free and free of temperature variations. Storage temperature -40 °C to +80 °C, and these limits
must not be exceeded.
Check the silent, free movement of the impeller. When transhipping (especially over longer distances) check if the
packaging is adequate for method and manner of transportation. Damages due to improper transportation, storage or
commissioning are not liable for warranty.
2 .5
Series version
These installation and operating instructions describe the Helios centrifugal cooling air fan B KLG ... series:
Centrifugal cooling air fan
Centrifugal cooling air fan
Binding information on the individual centrifugal cooling air fan types can be found on the type plate.
2 .6
Performance data
The motor type plate gives an indication of the electrical values, which must be coordinated with the local supply
network.
2 .7
Disposal
All relevant requirements and regulations which are applicable in the destination country must be observed for disposing
the unit.
2 .8
Technical data
Max. cooling air volume
Cooling air temperature
Condensate drain hole
Voltage
Frequency
Current
Output
Min/max. ambient temp..
Speed
Wiring diagram
Weight
Humidity protection class
Insulation class
Material casing/impeller
Motor protection
Type
B KLG 500
Type
B KLG 1000
B KLG 500
B KLG 1000
500 m
3
/h
1030 m
3
/h
40 °C
40 °C
–
Rotor side
230V
400V
50 Hz
50 Hz
0 .70 Amp .
0 .39 Amp .
160 Watt
175 Watt
0 to 70 °C
-25 to 60 °C
2400 1/min
1330 1/min
SS-1019
SS-1018
3 .5 kg
6 kg
F2 -2
F5
F
B
Alu ./steel sheet Steel sheet
Thermal cont .
–
3
Ref . no .
02798
Ref . no .
02799
Leakage current
< 0 .75 mA
Operating mode
S1
Installation position Any
Bearing Motor
Ball bearings
Direction of rotat.
Right looking at rotor
Protect. cat./class IP 44 / I
EN