Warranty Conditions - GYS NEOPULSE 400 CW Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Operating manual
The wire jams after passing through the
rollers.
The weld bead is porous.
Excessive sparks.
No gas coming from the torch.
Error while downloading.
Backup error.
Automatic deletion of JOBS.
Push Pull torch detection error.
USB key error.
File error.

WARRANTY CONDITIONS

The warranty covers any defects or manufacturing faults for two years from the date of purchase (parts and labour).
The warranty does not cover:
• Any other damage caused by transportation.
• General wear of parts (eg. : cables, clamps, etc.).
• Damage caused by misuse (incorrect power supply, the dropping or dismantling of equipment).
• Environmental failures (pollution, rust and dust).
In the event of a breakdown, return the appliance to your distributor, together with:
- dated proof of purchase (receipt, invoice, etc.),
- a note explaining the breakdown..
Translation of the original
instructions
Crushed wire guide sheath.
Wire jamming in the torch.
No capillary tube.
Wire speed too high.
The gas flow is insufficient.
Gas cylinder empty.
Unsatisfactory gas quality.
Air circulation or wind influence.
Gas nozzle is too clogged.
Bad wire quality.
Condition of the welding surface is too poor
(rusted, etc.).
The gas is not connected.
Arc voltage is too low or too high.
Poor earth connection.
Insufficient gas protection.
Poor gas connection.
The data on the USB stick is incorrect or
corrupted.
You have exceeded the maximum number of
backups.
Some of your JOBs have been deleted
because they were incompatible with the new
pre-installed user settings (synergies).
-
There is no JOB detected on the USB stick.
The product's memory space is full.
The file does not match the pre-installed
user settings (synergies) downloaded to the
product.
NEOPULSE 400 CW
Check the sheath and torch.
Replace or clean.
Check that the capillary tube is present.
Reduce the wire speed.
Adjustment range from 15 to 20 L / min.
Clean the base metal.
Replace it.
Replace it.
Avoid draughts and protect the welding area.
Clean or replace gas nozzle.
Use a wire suitable for MIG/MAG welding.
Clean the workpiece before welding.
Check that the gas is connected to the power
source's inlet.
See welding settings.
Check and position the earth clamp as close
as possible to the area to be welded.
Adjust the gas flow.
Check the connections of gas inlets.
Check that the solenoid valve is working.
Check your data.
You need to delete some programs.
The number of backups is limited to 500.
-
Check Push Pull torch connection.
-
Free up some space on the USB key.
The file was created with pre-installed user
settings (synergies) that are not present on the
machine.
41