Rating Plate Information - Continental Fireplaces CDVS500N Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8
8
2.4

RATING PLATE INFORMATION

2.4
RATING PLATE INFORMATION
EN
EN
DIRECT VENT GAS FIREPLACE APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED
STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280.
WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR USE ONLY WITH
BARRIER W565-0196. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
*ALTITUDE DOWNRATING CONDITIONS APPLY
TO CANADA ONLY /
NOT FOR USE WITH SOLID FUEL
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
B-VENT MODELS GS50/CS500
APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION.
THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER
KIT GS-150KT.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
For rating plate location, see "INSTALLATION OVERVIEW" section
For rating plate location, see "INSTALLATION OVERVIEW" section
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
model, venting and gas type of the unit.
NOTE: This rating plate must remain with the appliance at all times. It must not be removed.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and shall be installed.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and shall be installed.
W415-1430 / 01.13.15
W415-1430 / B / 07.31.18
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
9700539 (WSL)
4001658 (NAC)
COLONNE D'EAU(GN)
NATURAL GAS MODEL
GDS50-N
CDVS500-N
COLONNE D'EAU (GN)
GS50-N
CS500-N
2000-4500FT
0-2000FT
COLONNE D'EAU (GN)
(0-610m)
(610-1370m)
44,000 BTU/h
40,000 BTU/h
20,000 BTU/h
18,000 BTU/h
33,000 BTU/h
30,000 BTU/h
31,200 BTU/h
28,400 BTU/h
70% / 69.5%
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
A
7"
B
2"
C
1"
20" TO CEILING FROM STOVE TOP
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY.
LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT.
s
FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN
VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR
LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POUR
UNE UTILISER SEULMENT AVEC BARRIÈRE W565-0196. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT
4001657 (NGZ)
4001659 (WUSA)
ALTITUDE / ELEVATION
*INPUT / ALIMENTATION*
REDUCED INPUT / ALIMENTATION REDUITE
OUTPUT(MODEL GDS50) RENDEMENT
OUTPUT(MODEL GS50) RENDEMENT
P4 (NG/LP) / (GN/PL):
D
17½"
E
6¼"
F
9½"
SERIAL NUMBER / NO. DESERIE
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
PROPANE MODEL
MIN SUPPLY PRESSURE: 11" W.C. (LP)
GDS50-P
CDVS50-P
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
GS50-P
CS500-P
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
0-2000FT
2000-4500FT
COLONNE D'EAU (P)
(610-1370m)
(0-610m)
36,000 BTU/h
40,000 BTU/h
*LES CONDITIONS DE BAISSE D'EVALUATION SELON L'ALTITUDE
18,000 BTU/h
21,000 BTU/h
S'APPLIQUENT AU CANADA SEULEMENT
27,400 BTU/h
30,400 BTU/h
30,000 BTU/h
26,400 BTU/h
70% / 69.5%
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE
UTILSE AVEC CET APPAREIL
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC
CETTE UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU
DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI
EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPARIEL DE CHAUFFAGE
B-VENT MODELS GS50/CS500
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO.
CET APPAREIL DOIT ETRE INSTALLE EN UTILISANT UN ENSEMBLE ADAPTATEUR
GS-150KT.
GDS50
DANS LE MANUEL D'INSTALLATION.
W385-1999

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Cs500nCdvs500pCs500p

Table des Matières