For optimum flame appearance and appliance operation, keep the vent length and number of elbows to a
For optimum fl ame appearance and appliance operation, keep the vent length and number of elbows to a
minimum. It is recommended that all horizontal runs have a minimum 1/4" (6.4mm) rise per foot /meter. The
minimum. It is recommended that all horizontal runs have a minimum 1/4" (6.4mm) rise per foot /meter. The
air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify
air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify
EN
EN
EN
that it is unobstructed and undamaged. Rigid and flexible venting systems must not be combined. Different
that it is unobstructed and undamaged. Rigid and fl exible venting systems must not be combined. Different
venting manufacturers components must not be combined.
venting manufacturers components must not be combined.
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal
run is 20 feet (6m). The maximum allowable vertical vent length is 40 feet (12m). The maximum number of vent
run is 20 feet (6m). The maximum allowable vertical vent length is 40 feet (12m). The maximum number of vent
connections is two horizontally or three vertically (excluding the appliance and the air terminal connections) when
connections is two horizontally or three vertically (excluding the appliance and the air terminal connections) when
using exible venting.
using exible venting.
Deviation from the minimum vertical vent length can create difficulty in burner start-up and/or carboning.
Deviation from the minimum vertical vent length can create diffi culty in burner start-up and/or carboning.
Use an adjustable pipe as the final length of rigid piping to the stove for ease of installation.
Use an adjustable pipe as the fi nal length of rigid piping to the stove for ease of installation.
3.2
TYPICAL VENT INSTALLATION
3.2
TYPICAL VENT INSTALLATION
3.2
TYPICAL VENT INSTALLATION
(73.7cm)
29" (737mm)
29" (737mm)
MINIMUM
MINIMUM
30 3/4"
30 3/4"
(78.1cm)
(781mm)
(781mm)
* See "VENTING" section
* See "VENTING" section
W415-1430 / B / 07.31.18
W415-1430 / 01.13.15
W415-1430 / 01.13.15
(86.4cm)
34" (864mm)
34" (864mm)
MAXIMUM
MAXIMUM
59 3/4"
59 3/4"
(151.8cm)
(1518mm)
(1518mm)
MINIMUM
MINIMUM
PLUS RISE*
PLUS RISE*
8.5A
16" (406mm)
(40.6cm)
16" (406mm)
MINIMUM
MINIMUM
40 FT
40 FT
(12m)
(12m)
MAXIMUM
MAXIMUM
36" (914mm)
(91.4cm)
36" (914mm)
MINIMUM
MINIMUM
30 3/4"
30 3/4"
(78.1cm)
(781mm)
(781mm)