Atag HI8071M Notice D'utilisation page 108

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION DIMENSIONS
Additional requirements for the integration (flush installation) of the hob (HI8071I)
- The hob can only be integrated above a single cupboard at
least 800 mm wide.
- Once it has been integrated, the hob must remain accessible
from underneath for service purposes. If a drawer or oven is
built in under the hob it must be easily removable.
- These hobs are particularly suitable for integration in stone or
tiled worktops.
- When integrating the hob it should only be kitted along the
side of the glass top and not at the bottom. This is to ensure
that the glass top itself remains accessible should it need to be
replaced. To do this, apply a layer of tape, such as masking
tape, to the inlay surface.
- Report any transit damage before sealing the hob. Any
damages reported afterwards will be deemed a result of it
being built in.
- The guarantee does not cover damages resulting from the hob
being built in.
- The guarantee does not cover water damage or any other
damage to the worktop the hob is built into.
- Prior to any service call, all interior parts of the cupboard the
hob is built into, such as drawer constructions, shelves, racks
and runners, are to be removed.
- The service department is responsible for the repair and
service of the hob only. You should contact your kitchen
specialist about the re-integration (flush installation) of the
hob.
- The kit used to seal the edges of the glass top must be
resistant to temperatures of at least 160 °C.
- To prevent discolouration of the natural stone, use a specially
developed sealant between the glass and natural stone.
GB 23
installation instructions

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hi8071i

Table des Matières