4.4
Stop
a) stop the dryer 2 minutes after the air compressor stops or in
any case after interruption of the air flow;
b) make sure compressed air does not enter the dryer when the
dryer is disconnected or if an alarm occurs.
x
c) Press
: the POWER LED (2) turns yellow again;
&
d) Turn the MAIN SWITCH
to "O OFF" to switch the
power off.
Y
Wc version, close the water circuit with the dryer stopped.
5
Control
5.1
Control panel
3
Display
[
è
&
z
y
4
5
é
x
2
English
Reference
Name
1
MAIN SWITCH
2
2
POWER LED
POWER LED
ENERGY SAVING
3
LED
4
4
WARNING LED
WARNING LED
5
DRAIN LED
Keypad mode
x
Switching on/off
ON/OFF BUTTON
z
Reset alarm/ warning
RESET BUTTON
é
1
Alarm/warning log
HISTORY BUTTON
y
Condensate drain
DRAIN BUTTON
* returns to STANDARD mode after 5 minutes.
Description
I ON = dryer powered;
O OFF = dryer not powered.
Yellow = dryer powered.
Green = Dryer operating.
Lit = Dryer in energy saving
condition.
Off = no signal.
Flashing = Alarm or warning.
Lit = Drain open.
STANDARD
MENU*
Confirm
Up
Down
Out
5.2
Operation
Operation status
&
With the MAIN SWITCH
turned to "I ON" (dryer pow-
ered) three working conditions are possible:
[
DRYER
DISPLAY
STATUS
1
OFF
Off
2
ON
Dew point
3
REMOTE OFF
r.OF
To switch from OFF to ON (and vice versa) press
!
In OFF status the unit remains powered until the MAIN
&
SWITCH
is turned to "O OFF"!
Y
To manage REMOTE OFF mode, remove the bridge
between terminals X4.0 and X4.10 (see par. 8.8) and connect the
remote start/stop switch (to be provided by the customer).
In ON status, use the button with the following logic:
X4.0
X4.10
DRYER STATUS
ON
!
Do not activate ON status (refrigeration compressor operat-
ing) more than 10 times in one hour.
PDRD265 ---1000
POWER LED (2)
Yellow
Green
Yellow
x
.
X4.0
X4.10
REMOTE OFF