There are 3 potentiometers on the UST1-FU control unit.
You can set slow movement in both directions with potentiometer 1. You can separately set the lifting and
lowering speeds with potentiometers 2 and 3, respectively.
X11
10 – English
SETTING THE SPEED
POTENTIOMETER 2
POTENTIOMETER 3
POTENTIOMETER 1
V
U
J11
Single-phase INVERTER
B1
B2
X2
J10
connection
J11
W
U
V
L1
L2
INVERTER
Three-phase
INVERTER connection
J10
PE
B1
B2
L3