general information
EN
1.3

rating plate information

Certified to Canadian and American National Standards: CSA 2.22-2016 / ANSI Z21.50-2016 for Vented Decorative Gas Appliances
Certifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-2016 / ANSI Z21.50-2016 pour les Appareils à gaz décoratif à évacuation
Direct vent, vented gas fireplace. Approved for bedroom, bathroom and bed-sitting room installation. Suitable for mobile home installation, if installed in accordance with the current
standard CAN / CSA Z240MH Series gas equipped mobile homes in Canada, or, in the United States, the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part
3280. When this US Standard is not applicable, use the Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities, ANSI / NFPA 501A. This appliance
must be installed in accordance with local codes, if any; if none, follow the current ANSI Z223.1 or CSA B149. For use with barrier W565-0209. Follow installation instructions.
Foyer à gaz ventilé. Homologué pour installation dans une chambre à coucher, une salle de bain et un studio. Approprié pour installation dans une maison mobile si son installation
conforme aux exigences de la norme CAN / CSA Z240MH Séries de maisons mobile équipées au gaz en vigueur au Canada, ou, aux États-Unis selon la norme 24 CFR, Part 3280,
Manufactured Home Construction and Safety Standard. Dans le cas ou cette norme d'États-Unis n'est pas pertinentes, utiliser la norme NFPA 501A, Fire Safety Criteria for Manufactured
Home Installations, Sites and Communities. Installer l'appareil selon les codes ou règlements locaux ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1 ou
CSA B149 en vigueur. Utiliser uniquement avec l'écran W565-0209. Suivre les instructions d'installation.
9700539 (WSL)
B35NT
B35NTE
Altitude
Input
Reduced Input
14,000 BTU/h
G
P4
Manifold Pressure: 3.5" w.c. (NG)
Minimum Supply Pressure: 4.5" w.c. (NG)
Maximum Supply Pressure: 7"* w.c. (NG)
Pression au Collecteur: 3,5" d'une colonne d'eau (GN)
Pression d'Alimentation Min.: 4,5" d'une colonne d'eau (GN)
Pression d'Alimentation Max.: 7"* d'une colonne d'eau (GN)
*Maximum inlet pressure not to exceed 13".
Minimum clearance to combustible materials:
Sides & back: per standoff spacers for framing and finishing
materials. For non-combustible framing and finishing materials,
see installation manual.
G
Top 0"
Floor 0"
Sides 0"
Back 0"
Vent top 3"
Vent sides & bottom 1"
Mantel 12"**
**Maximum horizontal extension: 2". See installation manual
for greater extensions, minimum vent lengths and maximum
vent lengths.
WOLF STEEL LTD.
24 Napoleon Road, Barrie, ON, L4M 0G8 Canada
MAX SIZE: 8.5" X 4.75"
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
HOLE TO BE 0.250"Ø / 0.312" FROM EDGES
MATERIAL:
CLASS III
A-2, PERMANENT LABEL, WATERPROOF, 0.010 IN. VELVET MATTE LEXAN AND/OR 0.050 IN. HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A MAXIMUM
note:
TEMPERATURE OF 175°F (79°C).
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "NE CONVIENT PAS AUX COMBUSTIBLES SOLIDES. " TO BE 10 POINT VOGUE, BOLD FACE, UPPER CASE AND 2
The rating plate must remain with the appliance at all times. It must not be removed.
POINT LEADING SPACING OR EQUIVALENT.
BLACK LETTERING ON WHITE BACKGROUND.
SERIAL NUMBERS TO BE ASCENDING FROM B35218130
WOLF STEEL LTD.
1.4

mobile home installation

TITLE: LABEL, RATING PLATE
REVISION:
G: Corrected recessed depth + P4 efficiency + added CSA energy label || 09.27.18_P.H.
This appliance must be installed in accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4" (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
note:
Conversion kits are not available for Vent Free appliances.
8
W415-1399 / D / 10.15.18
4001658 (NAC)
4001657 (NGZ)
MODEL / MODÈLE
CB35NT
CB35PT
CB35NTE
CB35PTE
0-4500ft (0-1370m)
20,000 BTU/h
15,500 BTU/h
41.6%
Minimum Supply Pressure: 11" w.c. (P)
Maximum Supply Pressure: 13"* w.c. (P)
Pression au Collecteur: 10" d'une colonne d'eau (P)
Pression d'Alimentation Min.: 11" d'une colonne d'eau (P)
Pression d'Alimentation Max.: 13" d'une colonne d'eau (P)
*Pression d'alimentation maximale ne devait pas dépasser 13".
Dégagements minimaux des matériaux combustibles:
Côtés et arrière: selon les espaceurs de dégagements pour les
matériaux d'ossature selon le manuel du propriétaire pour les
Recessed depth 18 9/16"
Profondeur d'encastré 18 9/16"
Côtés et dessous du conduit d'évent 1"
**L'extension horizontale maximale: 2". Référez au manuel d'installation
pour des extensions plus grandes, les longueurs d'évacuation minimaux et
B35(N)T(E) / B35(P)T(E)
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF
4001659 (WUSA)
HEAT, NOT INTENDED FOR USE AS A HEATING APPLIANCE,
B35PT
NOT FOR USE WITH SOLID FUEL.
B35PTE
APPAREIL À GAZ DÉCORATIF À ÉVACUATION: N'EST PAS
Élévation
UNE SOURCE DE CHALEUR; N'EST PAS DESTINÉ À ÈTRE
Alimentation
UTILISÉ COMME UN APPAREIL DE CHAUFFAGE; NE
Alimentation Réduite
P4
CONVIENT PAS AUX COMBUSTIBLES SOLIDES.
Manifold Pressure: 10" w.c. (P)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE
CERTIFIÉES AVEC L'APPAREIL.
WARNING
:
Do not add any material to the appliance which will come in contact with the
flames, other than that supplied by the manufacturer with the appliance.
AVERTISSEMENT
contact avec les flammes autre que celui qui est fourni avec cet appareil par le fabricant.
The appliance must be vented using the appropriate Napoleon vent kits. See installation
matériaux de finition.
manual for venting specifications. Proper reinstallation and resealing is necessary after servicing
Dessus 0"
the vent-air intake system.
Plancher 0"
L'appareil doit être ventilé à l'aide de l'ensemble d'évacuation propre à Napoleon. Référez au
Côtés 0"
manuel d'installation pour les spécifications d'évacuation. Il est nécessaire de bien réinstaller et
Arrière 0"
resceller l'évacuation après avoir executer l'entretien du système de prise d'air.
Dessus du conduit d'évent 3"
Optional fan kit: AUB
Ensemble de ventilateur facultatif: AUB
Tablette 12"**
Electrical rating: 115V, 60HZ. Less than 12 amperes.
Spécifications électriques: 115V, 60HZ. Moins de 12 ampère.
maximum.
Serial Number / N° de Série:
Insert
testing
agency
logo
REFERENCE# 161746
:
N'ajoutez pas à cet appareil aucun matériau devant entretien
B35
W385-1925 / G
PAGE 1 OF 2
DWG#: W385-1925
DATE: 07.30.13
20.1

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

B35ntB35nteB35ptB35pte

Table des Matières