Equipment Specifications; Feed Water Chemistry Requirements; Mechanical Specifications - Watts OneFlow OF744-10 Manuel D'installation, De Fonctionnement Et D'entretien

Système antitartre
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Equipment Specifications

Watts OneFlow
systems are complete, self-contained, loaded
®
with media and ready to use. A simple inlet and outlet connec-
tion is all that is required for installation. Please review operat-
ing pressures, temperatures and water chemistry limitations to
ensure compatibility.
a
d
b
c
e

Feed Water Chemistry Requirements

pH
Hardness (maximum)
Water Pressure
Temperature
Free Chlorine
Iron (maximum)
Manganese (maximum) 0.05 ppm
Copper
Oil & H2S
Polyphosphates
Silca (maximum)
* See note about iron, manganese and copper on the next page.
WARNING
!
*High levels of Copper will foul OneFlow media and typically
originates from new Copper plumbing. Wait a minimum of
4 weeks before placing system in operation. Avoid apply-
ing excess flux on the inner surfaces of the pipe and to use
a low-corrosivity water soluble flux listed under the ASTM
B813 standard.
NOTICE
** OneFlow media does not reduce silica scaling. Silica can act
as a binder that makes water spots and scale residue outside
the plumbing system difficult to remove. This 20 ppm limita-
tion is for aesthetic purposes.

Mechanical Specifications

Model
744
Max Service Flow
10
(gpm)
Dry Weight (lbs)
22
Service Weight (lbs)
80
Dimensions
(nominal - inches)
a
47
b
46
c
d
1.0
e
3.0
Using OneFlow
with other water treatment
®
equipment.
Due to the unique properties of OneFlow
unique requirements for using OneFlow
tion or other forms of water treatment.
1. OneFlow
must be the last stage in the treatment chain. Do
®
not install any filters after OneFlow
which scale prevention is required. POU drinking water filters,
e.g. carbon or RO are exempt from this requirement.
2. Do not apply phosphate or any other antiscalant either before
or after OneFlow
.
®
3
6.5-8.5
75 grains (1282 ppm CaCO3)
15psi to 100psi (1.03 bar to 6.9 bar)
40°F to 110°F (5°C to 43°C)
< 2 ppm
0.3 ppm
1.3 ppm*
Must be Removed Prior to OneFlow
Must be Removed Prior to OneFlow
20 ppm**
844
948
1054
12
16
20
25
29
35
97
129
168
47
49
58
46
48
57
7
8
9
10
1.0
1.0
1.0
3.0
3.0
3.0
, there are some
®
in conjunction with filtra-
®
or before any devices for
®
1252
30
43
235
55
54
12
1.0
3.0

Publicité

Table des Matières
loading

Table des Matières