Installation, Operation and
Maintenance Manual
Model OF1465-50TM, OF1665-75TM
OneFlow
Anti-Scale Systems
®
Chemical-Free, Salt-Free Scale Prevention
!
WARNING
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
Introduction
The Watts OneFlow
Anti-Scale System provides protection from
®
scale formation on internal plumbing surfaces. The OneFlow
tem can be installed at the point of entry to a building to treat both
hot and cold water, or it can be located directly before a water
heater, boiler, or other water using device that requires protection
from hard water.
OneFlow
prevents scale by transforming the normal dissolved
®
hardness minerals into undissolved crystal microparticles. These
crystals stay suspended in the water and have a greatly reduced
ability to react and attach to surfaces like dissolved hardness
does. Therefore the problem of internal buildup of scale in pipes,
water heaters and on fixtures and glass is greatly reduced.
OneFlow
is not a water softener or a chemical additive (like anti-
®
scalants or sequestrants). It is a scale prevention device with proven
third party laboratory test data and years of successful residential
and commercial installation. OneFlow® is the one water treatment
device that effectively provides scale protection and is a great salt-free
alternative to water softening (ion exchange) or scale sequestering
chemicals. Laundry and warewashing chemistry will likewise require
adjustments.
OneFlow
Benefits
®
• Chemical-free scale prevention and protection – converts
hardness minerals to harmless, inactive microscopic crystals
making OneFlow
an effective alternative technology to a
®
water softener for the prevention of scale due to water hard-
ness
• Virtually maintenance free - no control valve
• Uses environmentally friendly technology by using no salt
or other chemicals to constantly add, no electricity and no
wastewater
• Improves efficiency of all water using appliances – both hot**
and cold
• Simple sizing & installation – all you need to know is pipe
size and the peak flow rate.
• Safe for landscaping and lawn watering. No need for costly
bypass plumbing.
sys-
®
• Compatible with all on-site and community wastewater treat-
ment systems.
• Perfect system for towns or communities where water soften-
ers are banned or restricted
• For high-flow applications, install multiple tanks in parallel
• OneFlow® does not remove minerals or add sodium to the
water supply
• OneFlow can be installed as pre-treatment to commercial
reverse osmosis systems (contact your Watts Representative
for further details)
** For hot water applications where feed water temperature is
100°F – 140°F (38° – 60°C), please consult ES-OneFlow-
HotWater.
!
WARNING
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
IOM-OF1465TM_OF1665TM
WQA Certified against NSF/ANSI
Standard 61 and 372 for Lead Free.

Publicité

Table des Matières
loading

Sommaire des Matières pour Watts OneFlow OF1465-50TM

  • Page 1 Therefore the problem of internal buildup of scale in pipes, • OneFlow can be installed as pre-treatment to commercial water heaters and on fixtures and glass is greatly reduced. reverse osmosis systems (contact your Watts Representative OneFlow is not a water softener or a chemical additive (like anti- ®...
  • Page 2 OneFlow media. For applications with copper concentration greater than 1.3 ppm, please consult Watts Water Quality Technical Service. To further minimize any problem with excess copper, avoid applying excessive flux on the inner surfaces of the pipe and use a low-corrosivity water...
  • Page 3: Equipment Specifications

    Models ASTMB813 standard. For applications with copper concentra- OF1465-50TM tion greater than 1.3 ppm, please contact Watts Pure Water OF1665-75TM Technical Service at 1-800-224-1299. *** Exceeding maximum flow can reduce effectiveness and void warranty.
  • Page 4 The tanks expand and contract with water pressure fluctuations. Flexible connectors will prevent plumbing and tank leaks. The EDP code for the suggested Watts 2" Flexible Connec- tors is C515285 (Two are included and required for installation).
  • Page 5 Alternative Method for Replacing the Media Replacing Media NOTICE Follow steps 1 – 6 then, Your OneFlow media should be replaced every (3) years. ® • Remove center distributor tube and lower basket and siphon all water from tank 1. Shut off the primary feed supply going to the OneFlow tank.
  • Page 6: Parts List

    7. Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made. 8. Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then current production.
  • Page 7 ósmosis inversa (comuníquese con dispositivo de tratamiento de aguas que proporciona, de forma eficaz, su representante de Watts para obtener más información). protección contra el sarro y es una muy buena alternativa sin sal a los ablandadores de agua (intercambio de iones) o a las sustancias químicas que aíslan el sarro.
  • Page 8 OneFlow. En el caso de aplicaciones con una concentración de cobre superior a 1,3 ppm, consulte al Servicio Técnico de Calidad de Watts Water. Para minimizar aún más cualquier problema con la sobreabundancia de cobre, evite aplicar un exceso de fundente en las superficies internas de la tubería y utilice un fundente soluble en agua...
  • Page 9: Especificaciones Del Equipo

    ASTM B813. En el caso de aplicaciones con una OF1465-50TM concentración de cobre superior a 1,3 ppm, comuníquese con el Servicio Técnico de Watts Pure Water al 1-800-224-1299. OF1665-75TM *** Exceder el caudal máximo puede reducir la eficacia e invalidar la garantía.
  • Page 10: Puesta En Marcha

    Los conectores flexibles evitarán las fugas en las tuberías y los tanques. El código EDP para las conexiones flexibles de 2 pulg. (5 cm) Watts sugeridas es C515285 (se incluyen dos necesarias para la instalación).
  • Page 11 Método alternativo para Reemplazo del medio reemplazar el medio AV I S O Siga los pasos 1 a 6 y luego: El medio del sistema OneFlow debe reemplazarse cada (3) años. ® • Elimine el tubo de distribución central y la cesta inferior, y sifone toda el agua del tanque.
  • Page 12: Lista De Piezas

    8. Watts Regulator Company se reserva el derecho de realizar cambios o sustituciones en las piezas o el equipo por materiales de valor o calidad equivalente y de producción vigente en ese momento.
  • Page 13: Avantages De Oneflow

    à l’osmose inverse (veuillez contacter éprouvées de tiers et des années d’installation résidentielle et votre représentant Watts pour obtenir un complément commerciale réussie. OneFlow® est le dispositif de traitement de d’information).
  • Page 14: Caractéristiques Techniques

    Pour des applications dont la concentration de cuivre dépasse 1,3 ppm, veuillez communiquer avec l’équipe d’assistance technique Watts Water. Pour réduire davantage tout problème d’excès de cuivre, évitez d’appliquer trop de flux sur les surfaces intérieures des tuyaux et utilisez un flux soluble à l’eau peu...
  • Page 15: Spécifications Sur L'équipement

    énuméré sous la norme ASTM B813. Pour des Modèles gal/min l/min applications dont la concentration de cuivre dépasse 1,3 ppm, veuillez OF1465-50TM communiquer avec l’équipe d’assistance technique Watts Pure Water OF1665-75TM au 1-800-224-1299. ***Le dépassement du débit maximum peut réduire l’efficacité et annuler la AV I S garantie.
  • Page 16: Installation Typique Pour Des Systèmes À Banque Unique Ou Multiple

    Des raccords flexibles empêcheront les fuites au niveau du réservoir et de la tuyauterie. Le code EDP pour le raccord flexible Watts de 2 po (51 mm) recommandé est C515285 (deux sont inclus et requis pour l’installation).
  • Page 17: Remplacement Des Médias

    Autre méthode pour le Remplacement des médias remplacement des médias AV I S Suivez les étapes 1 à 6 puis, Votre médium OneFlow doit être remplacé tous les 3 ans. ® • Retirez toute l’eau du réservoir du tube de distribution central, du panier inférieur et du siphon.
  • Page 18: Liste Des Pièces

    MARCHANDE OU D’ADAPTATION À UN BUT PARTICULIER. Le recours décrit dans le premier paragraphe de cette garantie constitue le seul recours à toute violation de la présente garantie. Watts Regulator Company ne saurait être tenue responsable de tout dommage accessoire, spécial ou indirect, y compris, sans s’y limiter : la perte de profits ou le coût afférent à...

Ce manuel est également adapté pour:

Oneflow of1665-75tm

Table des Matières