9.7
Timer setting for "Alarm Outlet" (3)
You can specify the trigger time of the "Alarm Outlet" (3) (to which a siren may be connected)
yourself. Enter the following key combination while in programming mode to do so:
56 TTT
TTT in this case stands for 001 to 999 seconds.
9.7.1 Activation mode for "Alarm Outlet" (3)
You can however activate the alarm outlet in different ways. For this purpose, this code lock
offers you convenient options to specify an activation mode.
Enter the following key combination in programming mode to assign the desired activation
mode:
55 C
C in this case stands for the desired mode type.
Mode types:
C = 0
No function
C = 1
allows the triggering of the alarm outlet in connection with the extended door moni-
toring (see chapter: "9.6.2 Setting activation mode for "Aux Out" relay contacts (6)".
C = 2
allows the triggering of the alarm outlet via the sabotage contact.
C = 3
allows mode types 1 and 2 together
9.8
Restore factory settings (RESET)
Proceed in the following sequence:
1) Remove your code lock from the power supply.
2) Move the Switch "Reset" (7) to ON position.
3) Reconnect the operating voltage again.
4) The internal signaller is now active.
5) Move the Switch "Reset" (7) to OFF position.
30