TECHNICAL SHEET - Piano II 600 mm
MODEL
Electric power
Power supply
Insulation class
Protection degree
Dimensions L x H x P
Fixing holes
HfxLf [Height x Lenght]
Lenght/
Type of electric cable
Service temperature
Storage temperature
Humidity
Regulation type
Temperature control
field
Certification
Packaging content
TOOLS REQUIRED FOR INSTALLATION
- Phillips screwdriver (if using the sockets supplied)
- Drill
- 8 mm wall drill (if using the plugs supplied).
CHARACTERISTICS OF THE APPLIANCE: appliance protected against water jets
INSTALLATION REQUIREMENTS
The product is not to be recessed. If installed near a wall,
respect the minimum distance of 10 cm to the left and to the right.
PIANO II 600/3
PIANO II 600/5
600 W
363x600x70 mm 606x600x70 mm 849x600x70 mm
194x305 mm
Total lenght 1,6mt / 3x1 mmq
Thermostat, microprocessor with weekly program,
8 Fischer fixings for concrete, solid bricks, hollow bricks, compact stone.
Install the radiator 20 cm from the ground.
PIANO II 600/7
1000 W
230V +/- 10% 50Hz
CLASSE I
IPX4
194x548 mm
194x791 mm
0 - 30°C
0 - 50°C
0 - 85 % with no condensation
open window detection
7 - 30°C
4 wall brackets -
27
[Fig. 3]
PIANO II 600/9
1400 W
1092x600x70 mm
194x1034 mm
Classe I
1800 W