Correct electrical installation
• Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
• A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the
recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regula-
tions.
• For your own safety, please consult a qualified electrician.
• The device may only be connected if the electrical data of the device and the power supply coincide. The device data
is to be found on the device type plate, on the packaging or in this manual.
• Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
• Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
• Install the transformer at a minimum safety distance of 2 m from the water.
• Protect the plug connection from moisture.
• Only connect the unit to a correctly fitted socket.
Safe operation
• Never operate the unit if either the electrical cables or the housing are defective!
• Do not carry or pull the unit by its electrical cable.
• Route cables/hoses such that they are protected from damage and do not present a tripping hazard.
• Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
• Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
• Only use original spare parts and accessories for the unit.
• Never carry out technical modifications to the unit.
• Only operate the unit with the supplied transformer.
• Keep the socket and power plug dry.
• The power pack and the plug connectors of the power cables supplied are not water-tight, but only rain and splash-
proof. Do not route or fit in the water.
• Do not look directly into the light source.
Set-up and start-up
The unit is supplied fully assembled as a complete set containing a power pack and three LED spotlights. When set up
above the water level, maintain a safety distance of at least 50 cm from combustible material. Ensure a safe seating.
Do not cover the unit. Danger of fire!
Position the unit such that it does not present a hazard for anybody. As an option, you can bolt the foot on a firm
ground or a load bearing wall (A1). Adjust the light tilt and arrest this angle with the screw connection (A2).
Connect the plug of the spot light power cable to the transformer socket. Plug the transformer power cable in the mains
socket. Check the spotlight function.
The LED light cannot be dimmed. The brightness of an LED reduces as the operating time increases.
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! The unit becomes very hot during operation.
Possible consequence: Combustible materials in the surrounding area could catch fire.
Protective measure: Do not operate the unit in the vicinity of combustible materials.