STATISTICS
Data on the machine operations is stored in both general
counters and relative counters, which can be reset without
losing total data.
TECH>
STATISTICS
Electronic counter
An electronic counter stores the total of all selections made
since the last reset.
Displaying general statistics
When pressing the confirm button " " the stored data is
sequentially displayed, and namely:
1 - single selection counter;
2 - counter by time bands;
3 - discount counter;
4 - failure counter;
5 - coin mechanism data.
Resetting general statistics
Statistics can be reset either globally (all types of data) or
partially for:
- selections
- discounts/overprice
- failures
- coin mechanism data
Press the confirm button " ", and the message "Confirm?"
starts blinking.
Press the confirm button " ", the message "Working" is
displayed for a few seconds and all statistics are reset.
Displaying relative statistics
When pressing the confirm button " " the stored data is
sequentially displayed with the same subdivision of the
general statistics.
Resetting relative statistics
Statistics can be reset either globally (all types of data) or
partially as in the general statistics.
Enabling the counters at start-up
This function is used to enable/disable the display of the
total number of sales since the last statistic reset, during
the start-up phase of the machine.
© by N&W GLOBAL VENDING SpA
TECH>
"List of statistics"
25
Printing
Connect an RS232 serial printer having a Baud rate of 9600,
8 data bit, no parity, 1 stop bit to the serial port located on
the push button board to print all the statistics described in
the paragraphs "Displaying general statistics" and "Display-
ing relative statistics". The printout will also contain the
machine information, the date and the software version.
Statistics can be printed partially or totally.
To connect the printer, do as follows:
- press the confirm print button " ", displaying the message
"Confirm?";
- connect the printer before confirming;
- press the confirm button " " again to start printing.
TEST
This group of functions is used for performing some
controls on the machine.
TECH>
TEST
Test dispensing
With this function it is possible to obtain, with the door open
and without inserting any money, for each selection dis-
pensing of:
- complete selection
- water only
- powder only
Special functions
By accessing this function it is possible to:
- activate the espresso brewer unit;
- release a dose of ground coffee; the dose is stored by
means of the confirm button " ";
- open a solenoid valve to allow the intake of air in the event
of emptying the boiler for maintenance;
- manually install the boiler;
Autotest
This function allows testing, in a semiautomatic way, of the
main machine components.
Press button " " and the message "AUTOTEST" will start
blinking.
It is possible to cancel each operation and go to the next one
by pressing button " ", confirming with button " " to start
the autotest routine.
Some checks occur automatically, others need the manual
operation of the monitored component.
For the actuation sequence refer to the programming
manual.
TECH>
"List of functions"
0512 264 - 00