supply voltage
10...35V DC
10...28V AC
2.
PRODUCT DESRCRIPTION
The EE99-1 transmitter series stands for multifunctionality, highest accuracy, easy
mounting and service.
The EE99-1 can be employed in all common applications by choosing the
appropriate housing combination.
Working temperature range of remote sensing probe is -50...180°C
The construction of the transmitter enables field calibration and local loop
calibration in a simple way.
2.1
Operating elements
1...PUSHBUTTON S2: - for 1 point humidity calibration (humidity < 50%RH)
1
2...CALIB LED:
2
3...PUSHBUTTON S1: - for 1 point humidity calibration (humidity > 50%RH)
3
PUSHBUTTON S1+S2: - to reset to factory calibration settings
4
4...STATUS LED:
3.
CONNECTION DIAGRAM
4.
DIMENSIONS (mm)
- for 2 point humidity calibration (low calibration point)
- for exit the calibration mode
- lit up permanently during the calibration mode
- lit up shortly when reset to factory calibration settings
- for 2 point humidity calibration (high calibration point)
- to store the calibration settings
⇒
- flashing
supply voltage applied / microprocessor is active
⇒
- constantly lit
humidity sensor element damaged
T-sensor passive
3-wire
10
(-58...356°F).