8

Diagnostics

LED status displays

8
Diagnostics
LED status displays
LED
Pos.
Colour
1
yellow
2
green
1
2
yellow/
+
green
66
Condition
Description
off
No communication with the PROFIBUS master.
blinking
Communication with the PROFIBUS master has been established
via the function module.
off
l
The function module is not supplied with voltage.
l
The standard device and/or the external voltage supply is
switched off.
blinking
The function module is supplied with voltage but is not connected
to the standard device.
Causes:
l
The standard device is switched off.
l
The standard device is in the initialisation phase.
l
The standard device is not available
on
The function module is supplied with voltage and is connected to
the standard device.
blinking
Internal function module error
l
E82ZAFP008