DESCRIPTION OF THE DISPLAY

Menu tree
Level 1
Level 2
a. Main info
A. Unit Status
b. Setpoint
c. On/Off
a. S tatus
B . Inputs /
O utputs
b. M anual
M anagement
c. Te st
a. I/O status
b. Regulation
c. Working hours
C . Compres sors
d. Energy Saving
e. Alarms
f. Configuration
g. Advanced
a. I/O status
b. Regulation
c. Driver EVD
D . Condens ers
d. Energy saving
e. Alarms
f. Configuration
g. Advanced
a. I/O status
b. Configuration
E. Evaporat or
c. Regulation
d. Driver EVD
a. O il
b. Defrost
F. Other
fun ctions
c. Econo mizer
d. Injection
e. Heat reclaim
Level 3
Description
Information of the different operational states
Setpoint modification
Regulation on/off
a. Digital Inputs
Configuration and status of the digital inputs
b. Analog Inputs
Configuration and status of the analog inputs
c. Digital Outputs
Configuration and status of the digital outputs
d. Analog Outputs Configuration and status of the analog outputs
a. Digital Outputs
Manual management of the digital outputs
b. Analog Outputs Manual management of the analog outputs
c. BLDC Output
Manual management of the BLDC output
a. Digital Outputs
Factory test of the digital outputs
b. Analog Outputs Factory test of the analog outputs
Configuration and status of the compressor's inputs/outputs
Parameters of the compressors regulation
Maintenance threshold and running time of the compressors
Not used
Configuration of the LP/HP security of the compressors
Hardware configuration of the system
Advanced configuration of the system
Configuration and status of the gascooler's inputs/outputs
Parameters of the gascooler's regulation
Not used
Energy saving, HP floating, winter time difference
Configuration of the LP/HP security of the gascooler
Hardware configuration of the system
Advanced configuration of the system
Configuration and status of the evaporator's inputs/outputs
Controller type connected (MPXPRO/Ultracella)
Not used
Not used
Configuration and status of the inputs/outputs of the oil
a. I/O status
management
b. Settings
Oil management configuration
a. I/O status
Configuration and status of the defrost inputs/outputs
b. Regulation
Defrost configuration
c. Info
Remaining time before the next defrost cycle
a. I/O status
Not used
b. Settings
Not used
Configuration and status of the inputs/outputs of the liquid
a. I/O status
injection
b. Settings
Liquid injection limit and differential
a. I/O status
Not used
b. Settings
Not used
28