Opening/Closing The Vacuum Cleaner; Changing The Filter; Cleaning The Fi Lter Element - Festool CTM 22 E SG Notice D'utilisation D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
3.4
Temperature control
A temperature fuse switches the dust ex-
tractor off before this reaches a critical
temperature to protect against overheat-
ing - switch dust extractor off and leave for
around 5 minutes to cool down.
If the dust extractor still cannot be switched
back on, please consult a Festool-service
centre.
3.5
Connecting an electric tool
Observe the maximum connected
load on the appliance plug socket
(see "Technical Data")!
Make sure that the electric tool is
switched off when plugging it in and
unplugging it.
Connect the electric tool to the appliance
plug socket (1.7).
3.6
Connecting pneumatic tools
Make sure that the pneumatic tool
is switched off when plugging it in
and unplugging it.
When the compressed-air module (1.8)
(452829; supplied ready with CTM 33 LE
SG and CTM 44 LE) is fi tted, the automatic
cut-in of the appliance also operates in
conjunction with compressed-air tools. We
also recommend fi tting of the VE supply
unit (452797). The supply unit fi lters and
oils the compressed air and allows the air
pressure to be regulated. An IAS connecting
piece (454757) is available for connecting
Festool compressed-air tools with the IAS
system. To ensure trouble-free functioning
of the automatic cut-in, the operating pres-
sure of the tool must be 6 bar.
4
Operation
4.1
Opening/closing the vacuum
cleaner
- Open retaining clamps (2.2),
- Raise upper part (2.4) until support catch
(2.5) engages.
Follow the reverse order to close the appli-
ance. You must raise the upper part slightly
before depressing or disengaging the support.
4.2
Changing the fi lter
During the following procedure, take
care not to raise dust more than is
unavoidable.
Wear a P2 breathing protection mask
with health-hazardous dusts!
a)
Changing the fi lter bag (3.4)
Order no.:
CTM 22 E SG
CTM 33 E SG/CTM 33 LE SG
CTM 44 E/CTM 44 LE
CTM 55 E
- Open the vacuum cleaner,
- Remove the used fi lter bag (see printed
text on fi lter bag),
- Dispose of the used fi lter bag in accord-
ance with statutory requirements,
- Thoroughly clean the dirt container (2.10)
and the space (3.1) for suction turbine
(wipe down with a damp cloth),
- Insert new fi lter bag (see printed text on
fi lter bag). Important: Press the fi lter
bag sleeve (3.3) fi rmly onto the dust ex-
traction fi tting (3.2)!
- Close the vacuum cleaner.
b)
Changing the filter element
(2.3)
Order no.:
Do not operate machine without a
fi lter element. This may damage the
motor.
- Open the vacuum cleaner,
- Remove the used fi lter element (see print-
ed text on the fi lter element packaging),
- Dispose of the used fi lter element in a
sealed, dust-tight bag in accordance with
statutory requirements,
- Thoroughly clean dirt container (2.10) and
space (3.1) for the suction turbine (wipe
down with a damp cloth),
- Fit a new fi lter element (see printed text
on the fi lter element packaging),
- Close vacuum cleaner.
4.3
Cleaning the fi lter element
To clean, move the handle (2.1) to and fro
about 10 times. N.B.: You need to clean the
fi lter element only if you use the vacuum
cleaner without a fi lter bag.
14
452970
452971
452972
452973
452923