5. TECHNICAL FEATURES

Resolu-
Function
Range
tion
DC
400 mV
0,01 mV
Voltage
4 V
0,0001 V
40 V
0,001 V
400 V
0,01 V
1 000 V
0,1 V
AC
Voltage
400 mV
0,1 mV
4 V
0,001 V
40 V
0,01 V
400 V
0,1 V
1 000 V
1 V
accuracy from 5 % to 100 % of range
400 µA
0,01 µA
DC
4 000 µA
0,1 µA
Current
40 mA
0,001mA
400 mA
0,01 mA
10 A
0,001 A
(20 A : 30 s maxi with reduced accuracy)
AC
400 µA
0,1 µA
Current
4 000 µA
1 µA
40 mA
0,01 mA
400 mA
0,1 mA
10 A
0,01 A
(20 A : 30 s maxi with reduced accuracy)
accuracy from 5 % to 100 % of range
Accuracy is valid from 18
DMM240
Authorized
Accuracy
overload
protection
±(0,06 % R + 2D)
1 000 V
±(0,1 % R + 2 D)
50 Hz to 1 000 Hz
±(1,0 % R + 4 D)
1 000 V
±(1,0 % R + 3 D)
Fuse HBC 500
±(1,0 % R + 3 D)
mA / 1000 V
Fuse HBC
10 A / 1000 V
50 Hz to1 000 Hz
Fuse HBC
±(1,5 % R + 3 D)
500 mA / 1000 V
Fuse HBC
10 A / 1000 V
o
o
C to 28
C, RH < 75%
31