Chapter II
1. Set the function switch to the
2. Insert the black test lead banana plug into the
negative COM terminal.
3. Insert the red test lead banana plug into the
positive + terminal.
4. Press the MODE key to indicate "Ω Ω Ω Ω ".
5. Touch the test probes to the points of the
circuit to be tested. It is best to disconnect
one side of the part to be tested so the rest of
the
circuit
will
not
measurement.
The
value
displayed.

3.6 Continuity test

To avoid any risk of deterioration, remove power from the
circuit to be tested before making any continuity
measurements.
1. Set the switch to the
2. Insert the black lead banana plug into the
negative COM terminal.
Insert the red test lead banana plug into the
positive + terminal.
3. Press the MODE key to display "
on screen
4. Apply test probes to the points of the circuit
to be tested
5. All resistance higher than 100 will stop the
instrument's sound alert. If the circuit is open,
"OL" is displayed on screen.

3.7 Diode test

To avoid any risk of deterioration, remove power
from the circuit to be tested before making any
diode measurements.
1. Set the function switch to the
2. Insert the black test lead banana plug into the
negative COM terminal and the red test lead
banana plug into the positive + terminal.
3. Press the MODE key to display
DMM240
position.
interfere
with
the
measured
is
position.
"and " "
position.
and V on screen.