Télécharger Imprimer la page

Fein FMM350Q Mode D'emploi page 8

Masquer les pouces Voir aussi pour FMM350Q:

Publicité

Les langues disponibles

Les langues disponibles

en
8
Extension cable.
If the use of an extension cord
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool. Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
Intended use of the power tool:
Hand-guided power tool for use without
water supply in weather-protected environ-
ments using the application tools and accesso-
ries recommended by FEIN.
Operation of the power tool off power generators.
This power tool is also suitable for use
with AC generators with sufficient power
output that correspond to the Standard
ISO 8528, design type G2. This Standard is
particularly not complied with when the so-
called distortion factor exceeds 10 %. When
in doubt, please refer to the generator
instruction/specification guide.
Symbols.
Symbol, character
Explanation
Observe the instructions in the text or graphic opposite!
Make sure to read the enclosed documents such as the Instruction Man-
ual and the General Safety Instructions.
Do not touch the saw blade. Danger of sharp application tools moving
back and forth.
Warning against sharp edges of application tools, such as the cutting
edges of the cutter blades.
Before commencing this working step, pull the power plug out of the-
socket. Otherwise there will be danger of injury if the power tool
should start unintentionally.
Use eye protection during operation.
Recommended dimensions of extension cords
at an operating voltage of 120 V – single-
phase a. c., with only FMM350Q connected:
Max. cable length, ft
≤ 100
100
200
–200
–300
Min. conductor size
A.W.G.
16
14
For sanding small surfaces, corners and edges,
for sawing thin parts of steel sheet, wood and
plastic parts, for scraping, polishing, rasping,
cutting and separating.
Operating the power tool off
WARNING
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
Max. cable length, m
≤ 30
30
– 60
Min. conductorcross-
2
section, mm
12
1.5
2.5
60
–100
4

Publicité

loading