Standby; Error Messages; Creating Profiles - Leister VARIMAT V2 Instructions D'utilisation

Masquer les pouces Voir aussi pour VARIMAT V2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
1. Work mode

1.9 Standby

• If the welding nozzle (9) is not in the welding position and no button is pressed
during a definite time, the Cool down mode will automatically start after the standby
time has passed.
The cooling down process is initiated.
• If the e-Drive
Standby mode, the display will change back to the initial state.
• For setting the standby time, (section 2.2, Standby setup)
1.10 Error message
• If a malfunction occurs in the automatic hot-air
welding machine VARIMAT V2, a message will
appear on the display (5), which is also pro-
vided with an error code. This code stands for
a more exact definition of the error which can be
seen in the lower list.
• In case of error 02 and error 40, separate
symbols are displayed
An acoustic warning signal will sound in the event of serious error messages
If the setpoint/actual welding temperature divergence is > 20 °C, an acoustic warning signal will sound
• In case of all other errors, the spanner is displayed for the service prompt
Error
Err01
Err02
Err04
Err08
Err40
2. Profile setup

2.1 Creating Profiles

• In the Profile Setup, 3 individual profiles can be created, in
which all three parameters can be freely set and then saved by
pressing the e-Drive
• The various menu items can be selected using the controls (4).
Pressing the e-Drive
selection.
Perform a test welding according to the welding instructions
of the material manufacturer and the national standards or guidelines. Approve the test welding.
30
is pressed before the countdown (180 seconds) has finished in
Type of error
Interruption or short-circuit of the temperature probe
Heating element defective (interruption in one/both winding(s)
Triac defective (one or both triacs are defective)
Blower motor defective
Undervoltage 25% (mains voltage 75%)
(see button combination)
.
will take you back to the Profile Setup

Publicité

Table des Matières
loading

Table des Matières