A
B
Type
Distance between
underside of the
extractor hood to
the hob
706 / 736
65 cm tot 70 cm
739
65 cm tot 70 cm
749
65 cm tot 70 cm
750
65 cm tot 70 cm
906 / 936
65 cm tot 70 cm
939
65 cm tot 70 cm
949
65 cm tot 70 cm
950
65 cm tot 70 cm
By means of the adjusting screw on the side wall the
extraction hood can be mounted flat.
706/ 736 / 739 / 906 / 936 / 939
749 / 750 / 949 / 950
See the table for mounting the attachment brackets.
Note the appropriate type number of the extractor hood!
Mark the holes for drilling and drill holes with an 8 mm
masonry bit at the points in the wall indicated in the
metal attachment brackets. Then insert the dowels and
screw on the attachment brackets, ensuring they are
horizontal.
C
Add up the number
of cm to the distance
selected (horizontal
line)
11 cm
11 cm
11 cm
11 cm
11 cm
11 cm
11 cm
11 cm
D
Distance in cm to the
left and right of the
perpendicular line up to
the bracket
16 cm
32 cm
32 cm
37 cm
16 cm
32 cm
35 cm
37 cm
The extractor hood can now be hung from the
attachment brackets. Hook the edges on the back of the
extractor hood into the edges present on the brackets.
Ensure that the extractor hood does not tilt forwards.
The extractor hood should preferably tilt to the rear. The
extractor hood can be levelled using the adjustment
screw on the side wall.
Installation under a kitchen cabinet
When installing under a kitchen cabinet, 4 holes have
to be drilled (for types 736, 739, 906, 936, 939) and 5
holes (for types 749, 750, 949, 950) with drill bit of 8
mm. Measure off the attachment holes on the extractor
hood and mark these on the cabinet
With the D 700 series, a hole must be cut in the
underside of the cabinet for the motor housing. With the
D 900 series, a hole must be cut in the underside of
the cabinet for an outlet pointing upwards. The extractor
hood is installed up against the underside of the cabinet.
The hood is attached to the cabinet with 4 or 5 bolts.
7 CONNECTING THE ELECTRICITY
The extractor hood is fitted with a connection cable
and an earthed plug. Insert the plug in an earthed wall
socket. Ensure that the plug is readily accessible if
the extractor hood needs to be disconnected from the
power supply.
The connection cable must be replaced by a qualified
professional. If the electric connection cable is
damaged, it must be replaced by an original Novy
connection cable.
Amperage and wattage are shown on the specification
plate.
E
E
Distance in cm
Distance in cm
between the
between the
centre and left
centre and right
brackets
brackets
x
x
x
x
26,5 cm
26,5 cm
29 cm
34 cm
x
x
x
x
38 cm
18 cm
38 cm
25 cm
EN 17