OPERATION INSTRUCTION OF THE CONTROL PANEL
1.3

Settings menu

The transition from the operating to setting menu occurs as specified in point 1.2.2.
With the page keys (see point 1.1, illustration text 5 and 6) individual displays of the setting menu
(point 1.3.1 – 1.3.26.) can be paged up or down.
1.3.1.
Setting the basic fan speed
MIN fan speed
1
1.3.2.
Moving to the operating menu
To main menu
Press + and -
1.3.3.
Delete weekly program
Delete
week program
1.3.4.
Programming the week program
Setti. week pro
Press + and -
d hr sp Tmp
1 12 5
20 Exit
d
day 1-7
1=monday, 2=thursday etc.
hr
hour 0 - 23
sp
fan performance step 1 - 8
Tmp supply air temperature 10 - 30 °C
Exit accept settings and quit.
N
no changes
d hr sp Tmp
1 7
2
17 Exit
d hr sp Tmp
1 16 4
20 Exit
d hr sp Tmp
1 19 6
N
Exit
d hr sp Tmp
1 21 4
N
Exit
The required fan speed steps are chosen with the + and – key. Speed steps from
0 to 8. The selected speed step is active when the clock timer is not switched on.
You can return to the main menu by pressing + and - buttons simultaneously.
In order to delete the week program, press + and - buttons simultaneously.
Press + and - buttons simultaneously to enter the weekly program.
With the weekly program the required fan capacity (fan basic air capacity) and the intake
air temperature of each week day and for each hour can be set. The weekly program
overwrites the manually entered control adjustments.
The CO
– and humidity control can increase the fan air capacity. It can however never
2
go below the fan basic air capacity set by the weekly program.
Exemplification: monday
The fan air capacity shall be lowered on main-days from 7:00 – 16:00 Uhr (meaning
7:00 o’clock a.m. – 4:00 o’clock p.m.) to speed step 2 and the intake air temperature to
17 °C. Afterwards the fan air capacity will be raised to speed step 4 and the intake air
temperature to 20 °C. In the evening the ventilation step for the sauna hours 19:00 –
20:00 Uhr (meaning 7:00 – 9:00 o’clock p.m.) will be raised to speed step 6, afterwards
*
it will be lowered again to speed step 4.
Move cursor with arrow key and change data with the + or – key.
Please note that: Finally approve the programming via Exit: Move cursor below the word
”Exit” and press + or – key.
Change ventilation step (sp) and intake air temperature* (Tmp) only for the hours, which
are to be changed, otherwise press (N) (no change).
Monday (d=1), 7:00 Uhr (meaning 7:00 o’clock a.m.) (hr=7), ventilation step (sp=2),
intake air temperature 17 °C (Tmp=17)
Move cursor to next hour.
Monday (d=1), 16:00 Uhr (hr=16) (meaning 4:00 o’clock p.m.), ventilation step 4 (sp=4)
Intake air temperature 20 °C (Tmp=20).
Move cursor to next hour.
Monday (d=1), 19:00 Uhr (hr=19) (meaning 7:00 o’clock p.m.), ventilation step 6 (sp=6)
Intake air temperature no change (Tmp=N)
Move cursor to next hour.
Monday (d=1), 21:00 Uhr (hr=21) (meaning 9:00 o’clock p.m., ventilation step 4 (sp=4)
Intake air temperature no change (Tmp=N)
Move cursor to the next day.
Suitable changes must be carried out for every day individually.
Finally exit the programming mode via Exit. The weekly program can be deleted if requested
(point 1.3.3), then renewed programming is possible. The programmed data are accessible
by selecting the day and by paging the time of day with the + or – key.
* ATTENTION: The KWL EC/ET 500 Pro has no electric heater battery.
Therefore the intake air temperature remains without effect.
14