Emerson AVENTICS IO-Link AF2 Notice D'instruction page 11

Capteur de débit
Masquer les pouces Voir aussi pour AVENTICS IO-Link AF2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
AVENTICS specific
427
Display unit
UInt
(0x1AB)
pressure
428
Switch off
UInt
display
(0x1AC)
429
Rotate display
UInt
(0x1AD)
430
Screensaver
UInt
(0x1AE)
431
Display bright-
UInt
(0x1AF)
ness
432
Display pin
UInt
(0x1B0)
433
Display 1 top
UInt
(0x1B1)
434
Display 1
UInt
bottom
(0x1B2)
435
Display 2 top
UInt
(0x1B3)
436
Display 2
UInt
bottom
(0x1B4)
437
Display 3 top
UInt
(0x1B5)
AVENTICS™ IO-Link AF2 | R412027828-BAL-001-AA | English
8 bits
rw 0 = bar
1 = psi
8 bits
rw 0 = off
1 = 1min
2 = 2min
5 = 5min
10 = 10min
30 = 30min
60 = 60min
8 bits
rw 0 = 0°
1 = 90°
2 = 180°
3 = 270°
8 bits
rw 0 = off
1 = 1min
2 = 2min
5 = 5min
10 = 10min
30 = 30min
60 = 60min
8 bits
rw 2 = 40%
7 = 60%
10 = 80%
15 = 100%
16 bits rw 0 ... 9999
Pin to protect the
configuration,
0000 ==> no pin
assigned
8 bits
rw 0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw 0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw 0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw 0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw 0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
AVENTICS specific
438
Display 3
UInt
bottom
(0x1B6)
439
Display history
UInt
(0x1B7)
440
Flow simulation
UInt
(0x1B8)
441
Temperature
UInt
(0x1B9)
simulation
442
Pressure
UInt
simulation
(0x1BA)
443
Flow medium
UInt
(0x1BB)
444
Reference
UInt
conditions for
(0x1BC)
the flow
445
Customer-spe-
Float
(0x1BD)
cific reference
pressure
446
Customer-spe-
Float
(0x1BE)
cific reference
temperature
447
Input zero point
Float
(0x1BF)
offset for flow
8 bits
rw 0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw 0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw 0 = 0%
10 = 10%
20 = 20%
30 = 30%
40 = 40%
50 = 50%
60 = 60%
70 = 70%
80 = 80%
90 = 90%
100 = 100%
255 = simulation off
8 bits
rw 0 = 0%
10 = 10%
20 = 20%
30 = 30%
40 = 40%
50 = 50%
60 = 60%
70 = 70%
80 = 80%
90 = 90%
100 = 100%
255 = simulation off
8 bits
rw 0 = 0%
10 = 10%
20 = 20%
30 = 30%
40 = 40%
50 = 50%
60 = 60%
70 = 70%
80 = 80%
90 = 90%
100 = 100%
255 = simulation off
8 bits
rw 0 = air
1 = nitrogen
2 = carbon dioxide CO2
3 = helium
4 = argon
8 bits
rw 0 = ISO8778
1 = ISO6358
2 = DIN1343
3 = DIN1945-1
4 = ISO1217
5 = ISO2533
6 = customer-specific
4
rw -1.0 ... 16.0
bytes
4
rw -20.0 ... 60.0
bytes
4
rw -10.0 ... 10.0
bytes
11

Publicité

Table des Matières
loading

Table des Matières