Operation; Inserting /Replacing Batteries - VOLTCRAFT MT-51 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10:
Hz% button
(When measuring current or voltage, frequency measurement can be additionally activated
by pressing this button.)
11:
HOLd button
(The hold button will record measured values, for example if the measured value is required
for later tasks as a reference value. Press the button at the desired moment to 'freeze' the
measurement reading; the display then shows "HOLD".)
12:
Backlight
(Press this button to activate the backlight on the display. Press the button again to deactivate
the backlight.)
13:
MOdE button
(When the measurement instrument is within the measurement ranges A, mA, µA and Ω/
/•))), pressing this button switches between AC and DC.)
14:
RANgE button
(When the measurement instrument is in the measurement ranges voltage and Ω, then
pressing this button will switch between AC and DC.)
15:
REL button
(So-called relative measurements allow you to conduct measurements relative to a certain
reference value. A reference value for e.g. voltage, current or capacitance can be saved
and then measurements relative to these stored values can be conducted. The displayed
reading will show the difference between the stored and the newly measured value.
Conduct the relevant measurements as described in the chapter Operation. Press the
REL button to save a measurement reading; "REL" will be displayed. The measurement
reading subsequently displayed is the difference between the stored and the newly
measured value.)
16:
NCV
(Non-Contact Voltage sensor for contactless voltage measurement. Hold the sensor in the
direction of an AC voltage source. For voltages within a range of 200 – 1000 V, the lamp
lights up.)
8.

OPERATION

Inserting /replacing batteries

do not leave batteries lying around as they could be swallowed by children or
pets. If this happens, seek immediate medical attention!
To ensure faultless operation of your multitester, it must be operated with an alkaline 9 V block battery (type
6LR61 or MN1604 or 6F22 or 006P). If the battery replacement symbol is displayed, the battery is to be
replaced. To do this, proceed as follows:
1.
Disconnect the measuring device from the measuring circuit and turn it off (range selection switch
to "OFF").
25