Flotec Easy Sump FPZS50RP Notice D'utilisation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation • Operation
7.
Once the Easy Sump is firmly seated in the base
of the pit, connect the check valve to the existing
discharge pipe and clamp it securely.
8.
Secure power cord and piggyback switch high up
and around pipe with a cable tie. Plug the pump
into a standard household 15 amp outlet.
NOTICE The circuit should be dedicated to the
sump pump exclusively.
Remember: Do no handle the pump whole it is
plugged in; whether it is running or not.
For parts or assistance, call Flotec Customer Service at
9.
To check the pump's operation, fill the sump pit
with water until the pump starts. Let it run until it
is pumped down the sump then stop. Once you're
satisfied that the pump is operating properly,
replace the sump pit cover.
Operation
Risk of electric shock. Can shock, burn or
kill. Do not handle a pump or pump motor with wet
hands or when standing on wet or damp surface, or in
water.
1. Shaft seal depends on water for lubrication. Do not
operate pump unless it is submerged in water as seal
may be damaged if allowed to run dry.
2. Motor is equipped with automatic reset thermal
protector. If temperature in motor should rise, switch
will cut off all power before damage can be done
to motor. When motor has cooled, switch will reset
automatically and restart motor. If protector trips
repeatedly, pump should be removed and checked.
Low voltage, long extension cords, clogged impeller,
very low head or lift, or a plugged or frozen discharge
pipe, etc., could cause cycling.
3. Pump will not remove all water. If operating a pump
manually and suddenly no water comes out of the
discharge hose, shut off the unit immediately. The unit
has broken prime due to a very low water level.
Risk of electric shock. Can shock, burn or
kill. Before attempting to check why unit has stopped
operating, disconnect power from unit.
1-800-365-6832
4

Publicité

Table des Matières
loading

Table des Matières