TABLE "C" - LEVEL 3° PROGRAMMING
Parameter
Definition
Default
PDM dynamic
PD
input polarity
Output AUX
Pa
polarity
Commands
CP
during pause
Special PDM
FP
functions
Radio chan-
nel 1
R1
command
selection
Select mains
HT
frequency
20 -
PERSEO CBD 230.P SD
INSTALLATION MANUAL
Cross Out
Setting Used
Input configured as NO
00
00
Input configured as NC
01
Output configured as NO
00
00
Output configured as NC
01
OFF
00
01
ON
01
None
00
Opening consent
01
00
Opening consent and pause time reset
02
TERMON enabling
03
Channel 1 deactivated
00
01
Channel 1 set as START
01
Channel 1 set as OPEN
02
30
20-80
Optional Extras
Description
The outputs can be configured as NO or NC, but in
the event of a power outage, the contacts will open
anyway
Depending on how the parameter is set, the automa-
ted device accepts or rejects commands during pause
time..
Not configured.
PDM is used to enable opening. Until it is pressed, no
opening command is accepted through the OPEN
input. If PDM is held down, no closing command is
accepted through the CLOSE input, meaning the
bollard stays open.
The PDM functions as described in point 1, but in case
of automatic logic, the pause time is reloaded.
The PDM function enables the TERMON system. Based
on the setting of the PD parameter, the closing or
opening of the contact activates or deactivates the
TERMON system. This makes it possible to interface a
schedule with a potential free contact to optimise the
heating system.