Connection

• Make the connection by pressing OK on the room sensor for
about 10 seconds until C1 appears in the top right-hand corner
of the display.
• Then advance with the OK button until C5 appears. Wait a
moment until the room sensor number appears.
Ch1 is room sensor 1
Ch2 is room sensor 2 (if there is one)
Select the correct room sensor by pressing OK again, to
confi rm and go to the next menu, C6.
• Menu C6 is used to control the signal strength when positioning
the sensor. The signal strength is shown in -dB (minus
decibels). Try to get as high a value as possible (-30 is higher
than -40). When the best possible signal has been found, press
OK to return to the main menu.
EN
• The room sensor number is now displayed in the top right
corner.
• Position the antenna. Use the heat pump's display of the signal
strength of the connected room sensor to fi nd a good position
for the antenna. Note that the display of the signal strength is
only updated when the room sensor has sent a value. To ensure
that this has happened, press the "OK" button on the room
sensor to update the signal strength.
• The diode on the antenna fl ashes green when it communicates
with the CTC control unit.
• The diode on the antenna fl ashes red when it communicates
with the room sensor.
32
CTC Wireless room sensor
Def heating circuit
Radiator system
Yes
Room sensor
Yes
Type
Wireless
Action
Association
Status
Dissociated
Level of signal
Battery
85 %
Version