Commissioning/start-up
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
N O T E
If the water flow is suddenly interrupted downstream of the outlet (e.g. with a slide valve), this can lead to a
brief increase of pressure of more than 1 bar (water hammer). Possible consequences: The unit may be da-
maged.
• Switching off: First switch off the pump, then close the slide valve. If the unit is operated in a filter system,
first take the filter system out of operation.
• Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a filter system,
start up the filter system last.
• Install the slide valve upstream of the inlet.
N O T E
New filters take approx. 3 to 4 weeks before the bacteria in the unit are fully established. During this time – or
at a water temperature of <10 °C – the filter may overflow. In this case the filter does not need to be cleaned.
• When using filter starter, medicines or pond water treatments, leave the UVC clarifying unit switched off for
at least 36 hours so as not to impair their efficacy.
Prerequisite
• First switch on the pump, then the UVC clarifier.
• Check all connections for leaks.

Switching ON/switching OFF

• Switching on: Insert the power plug into the socket.
– The unit switches on immediately.
• Switching off: Disconnect the power plug.
Check the function.
 I
• The function display is lit when the UVC lamp is switched on.
• An alternating light/dark blue glow in the inspection window indicates that the cleaning rotor is rotating.
Setting the bypass
The flow rate is controlled by the bypass. Depending on the setting, part of the water flows from the inlet directly out via
the opposite outlet. The remaining part of the water is irradiated by the UVC light and flows out via the second outlet.
Maximum cleaning capacity is only achieved with an optimum setting.
How to proceed:
 J
• Set both rotary handles to the delivery rate of the filter pump.
- EN -
19