To Stop Heater; To Restart Heater; Storage - Desa RLP30A Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPeratION
Continued
WARNING: Be sure motor
and fan are running before
pushing in automatic control
valve button. Flames could flash
outside heater if motor and fan
are not running.
6. Push in and hold automatic control valve
button (see Figure 5). Push piezo ignitor
button (see Figure 5). Keep pushing ig-
nitor button until the burner lights. When
burner lights, keep automatic control valve
button pushed in. Release button after
30 seconds. This activates the automatic
control system.
Note: If heater fails to ignite, hose may
have air in it. If so, keep automatic control
valve button pressed and wait 20 sec-
onds. Release automatic control valve
button and wait 20 seconds for unburned
fuel to exit heater. Repeat this step.
NOTICE: If heater is unplugged
or power outage occurs while
heater is running, the thermal
limit device will stop fuel flow.
A few seconds occur before the
thermal limit device activates.
During this short time, flames
may appear outside the heater.
This is normal. The flames will
go out when thermal limit device
activates.
Piezo
Ignitor
Automatic Control
Valve Button
Figure 5 - Automatic Control Valve
Button and Piezo Ignitor
6

TO STOP HEATER

1. Tightly close propane supply valve on
propane tank(s).
2. Wait a few seconds. Heater will burn gas
left in supply hose.
3. Unplug heater.

TO RESTART HEATER

1. Wait five minutes after stopping heater.
2. Repeat steps under To Start Heater,
page 5.
CAUTION: Disconnect heater
from propane supply tank(s).
1. Store propane tank(s) in safe manner. See
Chapter 5 of Standard for Storage and
Handling of Liquefied Petroleum Gases,
ANSI/NFPA 58. Follow all local codes.
Always store propane tanks outdoors.
2. Place plastic cover caps over brass fittings
on inlet connector and hose/regulator as-
sembly.
3. Store in dry, clean and safe place. Do
not store hose/regulator assembly inside
heater combustion chamber.
4. When taking heater out of storage, always
check inside of heater. Insects and small
animals may place foreign objects in
heater. Remove motor and other internal
parts if needed to remove foreign objects
(see Service Procedures, page 7).
www.desatech.com

StOrage

113855-01D

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rem30lpa35-facNlp35aRllp35aSpc-35Spc-40 ... Afficher tout

Table des Matières