Troubleshooting
Problem
Red LED does not illuminate and Battery (10) not charging
Battery has low capacity
Drill cannot be switched on
(Trigger Switch (7) does not move)
Drill does not start when Trigger Switch is pressed
Screws do not reach deep enough into the workpiece
Screws are driven too deep into the workpiece surface
Drilling performance poor with masonry
8
Possible cause
Battery not fully seated
Charger (13) not powered
Battery not being fully charged
Battery charged days before use
Battery has been charged over 100 times and capacity has
started to reduce
The Forward/Reverse Switch (6) may be in the middle
("locked") position
Battery completely discharged
Defective battery
Drill machine defective
Not enough torque; Torque Selector (3) setting too low
Low battery voltage
Too much torque; Torque Selector (3) setting too high
Hammer mode not selected
Drill bit tip worn or damaged
Very dense material
Solution
Clean Battery Connector (11) socket
Recheck mains connection
Charge the Battery for 4 – 5 hours
Charge the previous day or same day as use
This is normal for batteries. Contact your Silverline dealer to
purchase a replacement battery
Slide the Forward/Reverse Switch either to the left or right
Recharge battery or replace with a fully charged battery
Replace battery
Contact your Silverline dealer or authorised service centre
Choose a higher torque setting
Recharge battery or replace with a fully charged battery
Choose a lower torque setting
Enable hammer mode
Replace drill bit
Drilling speed will be slow in such material. A smaller pilot drill
can be drilled first to speed up the drilling process