Installer Instructions; Electrical Connection - Horeca Select GGW1001 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

WATER AND DRAIN CONNECTION:
The water tubes and the electrical power cable stick out from the back of the machine. Connect the water supply
tube to a ¾" threaded gas outlet.
Use only new tubes for the connection to the water supply; old or used tubes must not be utilized.
The dynamic supply pressure must be between 200 and 400 kPa; if the pressure is higher, a pressure reducer
must be installed.
A general faucet must be installed upon the water supply input tubing; the faucet must be accessible after
installation's completion. Do not install the faucet behind the dishwasher.
The declared cycle durations refer to a 50° hot water supply.
In case of cold water supply the duration of the cycle could increase in relation to the input water temperature,
since the dishwasher is equipped with a constant temperature and pressure rinse system.
DRAIN:
Every dishwasher comes equipped with a drain connection tube; this tube is intended to be installed at floor
level, with a trap drain.
Caution: make sure that the supply and drain tubes are not bent, restricted or crushed after
installation.

4.1 Electrical connection

The dishwasher's electrical connection, and that of eventual supplementary apparatus, is to be
entrusted to authorized and qualified personnel, with respect to the norms in vigor; the technical
regulations for the connections are also to be observed.
The total power installed is given upon the apparatus' technical data label.
Other apparatus must not be protected together with the dishwasher.
The user must provide for the installation, according to the norms in vigor, of a main electrical power
switch and of a differential switch compatible with the machine's characteristics.
These switches must be installed near the dishwasher, they must be easily accessible after
installation and it must guarantee complete disconnection from the electrical supply in category III
over voltage conditions.
Caution!!!
The dishwasher is free of electrical current only when the main switch is off.
Connect the apparatus to the usage equalizer. The
back of the machine.
The protection conductor (PE) is yellow-green colored, the neutral conductor (N) is blue colored and
the phase conductors (L1, L2, L3) are black, gray and brown colored.

4 INSTALLER INSTRUCTIONS

clamp for the connection is located at the lower