7.5 Additional prescriptions for safety applications with operator protection
functions
Provided that all previous requirements for the devices are fulfilled, for installations
with operator protection function additional requirements must be observed.
- The utilization implies knowledge of and compliance with following standards:
EN ISO 13849-1, EN 62061, EN 60204-1, EN ISO 12100.
- In the risk analysis, take into account that in manual start mode a possible sticking of
the start button can lead to an immediate activation of the module.
- If expansion modules or external contactors are used, make sure that they have
forcibly guided contacts and connect in feedback an NC contact of each device.
7.6 Limits of use
- Use the device following the instructions, complying with its operation limits and the
standards in force.
- The devices have specific application limits (min. and max. ambient temperature,
maximum currents, IP protection degree, etc.) These limitations are met by the device
only if considered individually and not as combined with each other.
- According to EU directives, this device is not intended for private use.
- The manufacturer's liability is to be excluded in the following cases:
1) Use not conforming to the intended purpose.
2) Failure to adhere to these instructions or regulations in force.
3) Fitting operations not carried out by qualified and authorized personnel.
4) Omission of functional tests.
- For the cases listed below, before proceeding with the installation contact our as-
sistance service (see paragraph SUPPORT):
a) In nuclear power stations, trains, airplanes, cars, incinerators, medical devices or
any application where the safety of two or more persons depend on the correct opera-
tion of the device.
b) Applications not contemplated in this instruction manual.
8 MARKINGS
The outside of the device is provided with external marking positioned in a visible
place. Marking includes:
- Producer trademark
- Product code
- Batch number and date of manufacture. Example: CS1-123456 (A21). The last part
of the production batch refers to the month of manufacture (A = January, B = February,
etc.) as well as the year of manufacture (21 = 2021, 22 = 2022, etc.).
9 TECHNICAL DATA
9.1 Housing
Material: Polyamide PA 66, self-extinguishing V0 acc. to UL 94
Protection degree:
Cable cross section:
Terminal tightening torque:
9.2 General data
SIL (SIL CL):
Performance Level (PL):
Safety category:
MTTF
:
D
DC:
PFH
:
D
Mission time:
Ambient temperature:
Storage temperature:
Mechanical endurance:
Electrical endurance:
Pollution degree:
Impulse withstand voltage U
:
imp
Rated insulation voltage U
:
i
Overvoltage category:
Air and surface distances:
9.3 Power supply
Rated supply voltage U
:
n
Supply voltage tolerance:
Max. DC residual ripple in DC:
Power consumption AC:
Power consumption DC:
9.4 Control circuit
Protection against short circuits:
PTC times:
Maximum resistance per input:
Current per input:
Min. duration of start impulse t
:
MIN
Response time t
:
A
Release time t
:
R1
Release time in absence of power supply t
Release time, delayed contacts t
:
R2
Simultaneity time t
:
C
9.5 Output circuit
Output contacts:
Contact type:
Material of the contacts:
IP40 (housing), IP20 (terminal strip)
0.2 ... 2.5 mm
(24 ... 12 AWG)
2
0.5 ... 0.6 Nm
Up to SIL CL 3 acc. to EN 62061
Up to PL e acc. to EN ISO 13849-1:2015
Up to cat. 3 acc. to EN ISO 13849-1:2015
(delayed contacts)
Up to cat. 4 acc. to EN ISO 13849-1:2015
(instantaneous contacts)
135 years
High
1.95 E-09
20 years
-25°C ... +55°C
-25°C ... +70°C
> 10 million operating cycles
> 100,000 operating cycles
external 3, internal 2
4 kV
250 V
II
acc. to EN 60947-1
24 Vac/dc; 50...60 Hz
±15% of U
n
10%
< 10 VA
< 5 W
PTC resistance, Ih=0.5 A
Response time > 100 ms, release time > 3 s
≤ 50 Ω
< 30 mA
> 100 ms
< 120 ms
< 20 ms
: < 200 ms
R
0.3 ... 3 s, 0.3 s steps
(articles CS AT-31••••)
1 ... 10 s, 1 s steps
(articles CS AT-32••••)
3 ... 30 s, 3 s steps
(articles CS AT-33••••)
30 ... 300 s, 30 s steps
(articles CS AT-34••••)
Time x s permanently set (article CS AT-30••••-TFx)
unlimited
2 instantaneous NO contacts;
1 delayed NO contact
forcibly guided
gold-plated silver alloy
Maximum switching voltage:
Max. current per contact:
Conventional free air thermal current I
Max. total current Σ I
2
:
th
Minimum current:
Contact resistance:
External protection fuse:
Maximum switching load:
Utilization categories acc. to EN 60947-5-1:
AC-15 (50 ... 60 Hz)
DC-13 (6 op. cycles/minute)
Utilization category acc. to UL 508:
9.6 Compliance with standards
EN 60204-1, EN ISO 13855, EN ISO 14118, EN ISO 12100, EN ISO 13850, EN 60529,
EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 60664-1, EN 60947-1, EN IEC 63000,
EN ISO 13849-1, EN ISO 13849-2, EN 62061, UL 508, CSA C22.2 n° 14-95,
GB/T14048.5-2017
9.7 Compliance with directives
Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU, RoHS Directive
2011/65/EU.
10 SPECIAL VERSIONS ON REQUEST
Special versions of the device are available on request.
These special versions may differ substantially from the indications in these operating
instructions.
The installer must ensure that he has received written information regarding the use
of the special version requested (see paragraph SUPPORT).
11 DISPOSAL
At the end of service life product must be disposed of properly, according to the
rules in force in the country in which the disposal takes place.
12 SUPPORT
The device can be used for safeguarding people's physical safety, therefore in case of
any doubt concerning installation or operation methods, always contact our technical
support service:
Pizzato Elettrica Srl
Via Torino, 1 - 36063 Marostica (VI) - ITALY
Telephone +39.0424.470.930
E-mail tech@pizzato.com
www.pizzato.com
Our support service provides assistance in Italian and English.
13 EC CONFORMITY DECLARATION
I, the undersigned, as a representative of the following manufacturer:
Pizzato Elettrica Srl - Via Torino, 1 - 36063 Marostica (VI) – ITALY
hereby declare that the product is in conformity with whatever prescribed by the
2006/42/EC Machine Directive. The complete version of the present conformity
declaration is available on our website www.pizzato.com
Marco Pizzato
DISCLAIMER:
Subject to modifications without prior notice and errors excepted. The data given in this sheet are accurately
checked and refer to typical mass production values. The device descriptions and its applications, the
fields of application, the external control details, as well as information on installation and operation, are
provided to the best of our knowledge. This does not in any way mean that the characteristics described
may entail legal liabilities extending beyond the "General Terms of Sale", as stated in the Pizzato Elettrica
general catalogue. Customers/users are not absolved from the obligation to read and understand our
information and recommendations and pertinent technical standards, before using the products for their
own purposes. Taking into account the great variety of applications and possible connections of the device,
the examples and diagrams given in the present manual are to be considered as merely descriptive; the
user is deemed responsible for checking that the specific application of the device complies with current
standards. This document is a translation of the original instructions. In case of discrepancy between
the present sheet and the original copy, the Italian version shall prevail. All rights to the contents of this
publication are reserved in accordance with current legislation on the protection of intellectual property. The
reproduction, publication, distribution and modification, total or partial, of all or part of the original material
contained therein (including, but not limited to, texts, images, graphics), whether on paper or in electronic
form, are expressly prohibited without written permission from Pizzato Elettrica Srl.
All rights reserved. © 2021 Copyright Pizzato Elettrica.
6/18
230/240 Vac; 300 Vdc
6 A
: 6 A
th
36 A
2
10 mA
≤ 100 mΩ
4 A
1380 VA/W
U
= 230 V, I
= 3 A
e
e
U
= 24 V, I
= 4 A
e
e
C300