Maintenance Intervals; Maintenance And Care; Maintenance Works; Maintenance Tasks - Kärcher HDS 5.0/30-4 S Eb Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Screw off supply hose at boiler bot-
tom and drain heating spiral empty.
Operate device for max. 1 minute
until the pump and conduits are
empty.
Flush device with anti-freeze
agent
Note
Observe handling instructions of the
anti-freeze agent manufacturer.
Fill anti-freeze agent of the trade into
swimmer container.
Switch on appliance (without heater)
till the appliance has been complete-
ly rinsed.
A certain corrosion protection is
achieved with this as well.

MAINTENANCE AND CARE

DANGER
Risk of injury! Always disconnect the
device from the electrical power supply
before performing maintenance or re-
pair work.
WARNING
Only use original spare parts.
After each work, turn off device, refer to
"After each operation".
Set the appliance switch to "0".
Disconnect the main plug from the
socket.
Shut off water supply.
Activate hand spray gun until device
is pressure less.
Remove water connection.
Allow device to cool down.
Your Kärcher vender will inform you
about the performance of a periodic
safety inspection resp. signing of a
maintenance contract.

Maintenance intervals

Weekly
Clean the sieve in the water connec-
tion.
Clean the fine filter.
Check oil level.
In case of lacteous oil inform Kärcher
customer service immediately
Monthly
Clean sieve in the water shortage
safe guard.
Clean filter at the detergent suck
hose.
After 500 operating hours, at least
annually.
Oil change.

MAINTENANCE TASKS

Clean the sieve in the water con-
nection
Figure 1 - Pos. 18
Take out sieve.
Clean sieve in water and reinstall.
Cleaning the fine filter
Figure 8
Unpressurize the appliance.
Unscrew lid with filter.
Clean the filter with clean water or
compressed air.
Reinstall in reverse sequence.
15
English

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hds 5.0/30-4 s ec

Table des Matières