OPERATION
WARNING
Never operate device with empty fuel
tank The fuel pump will otherwise be de-
stroyed.
Turning on the Appliance
Figure 2
Set the appliance switch to "I".
Indicator lamp for operational readiness
lights up.
Note
The temperature regulator must be at
"0" position because otherwise the
burner will switch off.
The device starts briefly and turns off,
as soon as the working pressure is
reached.
Note
If the indicator lamps for fuel, liquid soft-
ner or engine are on during operation,
turn off device immediately and repair
malfunction, refer to malfunctions.
Figure 6
Release the hand spray gun (A).
When activating the hand spray gun the
device switches back on.
Note
If no water comes out of the high pres-
sure nozzle, vent pump. Refer to mal-
functions "Device is not building up
pressure".
Adjust cleaning temperature.
Set temperature regulator to desired
temperature.
30 °C to 90 °C
– Clean with hot water.
12
English
100 °C to 150 °C
– Clean using steam.
Replace the high-pressure nozzle
with steam nozzle (refer "Using
steam").
Set working pressure and flow
Appliance setting
Figure 7
Turn the regulation spindle in a
clockwise direction: Increase work-
ing pressure (MAX).
Turn the regulation spindle in an
anti-clockwise direction: Reduce
working pressure (MIN).
Dosing of detergent
– For considerate treatment of the en-
vironment use detergent economi-
cally.
– The detergent must be suitable for
the surface to be cleaned.
Figure 2 - Pos. 7
With support of the detergent dose
valve set detergent concentration as
determined by the manufacturer.
Note
Recommended value at maximum
working pressure.
Proper use
Cleaning of: Machines, Vehicles, Struc-
tures, Tools, Facades, Terraces, Gar-
dening tools, etc.
DANGER
Risk of injury! Follow the respective
safety regulations when operating at
gas stations or other dangerous areas.
rate