Fayat Group DYNAPAC SD1800C 911 Manuel D'utilisation Et Entretien page 224

Finisseur
Table des Matières

Publicité

KWP
SPN
FMI
846
523452
2
849
1176
3
850
1176
4
856
523613
0
857
523613
0
858
523613
0
859
523613
0
860
523613
0
861
523613
1
862
523613
0
864
523613
2
876
523470
7
877
157
3
878
157
4
881
523633
11
882
523633
11
883
523633
11
887
3234
11
889
3224
1
892
4345
11
893
4343
11
894
4374
13
D 23.18 60
Code
Error Identification
1-4-3
Multiple Stage Switch engine torque limi-
tation curve; plausibility error
6-8-0
Sensor error pressure sensor upstream
turbine; signal range check high
6-8-0
Sensor error pressure sensor down-
stream turbine; signal range check high
1-3-4
Rail pressure disrupted
1-3-4
Rail pressure disrupted
1-3-4
Rail pressure disrupted
1-3-4
Rail pressure disrupted
1-3-4
Rail pressure disrupted
1-3-4
Minimum rail pressure exceeded
(RailMeUn3)
1-3-4
Rail pressure disrupted
1-3-4
Setpoint of metering unit in overrun
mode not plausible
1-4-6
Maximum rail pressure in limp home
mode exceeded (PRV)
1-4-7
Sesnor error rail pressure; signal range
check high
1-4-7
Sensor error rail pressure; signal range
check low
7-0-1
Nox conversion rate insufficient
7-0-1
Nox conversion rate insufficient
7-0-1
Nox conversion rate insufficient
8-0-7
Nox Sensor downstream of SCR Cataly-
sator; plausibility error "stuk in range"
8-0-8
Nox sensor upstream of SCR Catalysa-
tor; low signal not plausible
8-7-0
Sensor backflow line pressure (SCR);
plausibility error
8-7-1
General pressure check error (SCR)
8-7-2
Pressure stabilisation error dosing valve
(SCR)
Short Text Detail
Multiple Stage Switch engine torque limitation
curve; plausibility error
Sensor error pressure sensor upstream tur-
bine; signal range check high
Sensor error pressure sensor downstream tur-
bine; signal range check high
Maximum positive deviation of rail pressure
exceeded (RailMeUn0)
Maximum positive deviation of rail pressure in
metering unit exceeded (RailMeUn1)
Railsystem leakage detected (RailMeUn10)
Maximum negative deviation of rail pressure in
metering unit exceeded (RailMeUn2)
Negative deviation of rail pressure second
stage (RailMeUn22)
Minimum rail pressure exceeded (RailMeUn3)
Maximum rail pressure exceeded (RailMeUn4)
Setpoint of metering unit in overrun mode not
plausible
Maximum rail pressure in limp home mode
exceeded (PRV)
Sesnor error rail pressure; signal range check
high
Sensor error rail pressure; signal range check
low
Nox conversion rate insufficient (SCR-Cat
defect, bad AdBule quality)
Nox conversion rate insufficient (SCR-Cat
defect, bad AdBule quality); temperature range
1
Nox conversion rate insufficient (SCR-Cat
defect, bad AdBule quality); temperature range
2
Nox Sensor downstream of SCR Catalysator;
plausibility error "stuk in range"
Nox sensor upstream of SCR Catalysator; low
signal not plausible
Sensor backflow line pressure (SCR); plausibil-
ity error
General pressure check error (SCR)
Pressure stabilisation error dosing valve (SCR)

Publicité

Table des Matières
loading

Table des Matières