Standard model
1 Phase 1 Speed
115 V, 1Ph, 60Hz, 12A
Standard model
1 Phase 2 Speed
230 V, 1Ph, 50/60Hz, 16A
1
26
- EN
iii-1
iii

Installation procedures

Electric installation

AT T E N T I O N.: A N Y I N T E RV E N T I O N O N T H E
ELECTRICAL SYSTEM AND THE CONNECTION
OF A PLUG (WHEN NECESSARY), MUST BE
PERFORMED ONLY BY A QUALIFIED ELECTRICIAN,
I N C O M P L I A N C E W I T H T H E A P P L I C A B L E
STANDARDS AND NATIONAL LAWS AND/OR
LOCAL REGULATIONS.
The standard models of the tyre changers have specifi c
electrical specifi cations and are supplied according to
the diff erent power supplies that they will be connected
to; See the table aside
The electric motors operate with a voltage tolerance;
equal to more or less 10%.
The power supply cable, which is always provided with
the machine, must be fi tted with an adequately sized
type-approved plug, in compliance with the applicable
standards in the destination country.
For the installation technician
The qualifi ed electrician, when fi tting a plug, must refer
to the data clearly set out on the plate found on the
machine electrical cable.
The user must ensure that the electrical system that
the machine is connected to is fi tted with 10 A delayed
fuses (In case of machine with INVERTER 20 A (25 A
for Japan)), or alternatively, an equivalent automatic
magneto-thermic switch.
Check that there is an effi cient earthing system.
Once the connection is complete, press the self-
centring rotation pedal downwards (1, Fig. iii-1) and
check that it rotates clockwise.
Check that the power supply system is fi tted with an
automatic cut off device against overcurrents, with a
diff erential calibrated to 30 mA.
WARNING: IF INVERTERS ARE PRESENT, ONLY USE
TYPE B RESIDUAL CURRENT OPERATED CIRCUIT
BREAKERS.