7.8 Anti-legionnaire's disease protection (function activated only through the installer menu)

If activated, the water heater automatically carries out the anti-legionnaire's
disease protection function. The water is brought to a temperature of 65°C on a
monthly basis and for a maximum time of 15 minutes, so as to avoid germs from
developing in the water tank and piping (provided the water has not been
brought to T>57°C at least once for at least 15 minutes). The first heating cycle
is performed 3 days after the function has been activated. As these
temperatures may cause burns, it is advisable to use a thermostatic mixer.
During the cycle of antilegionella will be displayed "ANTI_B" alternately to the mode of operation, once the cycle is done
the set temperature remains the original one.
In the event that is enabled the two-tier rate signal HC-HP, the function will take place during the economic tariff. To
stop press "on/off".

7.9 Default settings

The appliance is manufactured with a series of default modes, functions or values, as indicated in the table below:
MAX. TEMPERATURE SETTABLE WITH THE HEATING
P2
P3

ANTI-LEGIONNAIRE'S DISEASE PROTECTION

P4
TIME_W (no. of accepted hours of powering)
P5
HC-HP (two-tier rate operation mode)
P7
MINIMUM SETTABLE TEMPERATURE
P8
DEFROST (active defrost activation)
PROGRAM P1 TEMPERATURE PRESET
PROGRAM P1 TIME PRESET
PROGRAM P2 TEMPERATURE PRESET
PROGRAM P2 TIME PRESET
Time setting
Adjustment of the maximum obtainable temperature (from 65°C to 75°C).
A higher temperature value allows for using a greater amount of hot water.
Activation/deactivation of the Anti-Legionnaire's Disease function (on/off). See
Paragraph 7.8
Maximum number of hours of daily heating (from 5h to 24h).
Activation/deactivation of the two-tier rate operation mode. See Paragraph 7.10
Resetting of all factory default settings.
Adjustment of the minimum obtainable temperature (from 50°C to 40°C).
A lower temperature setting allows for more energy-efficient operation in the event of
limited hot water consumption.
Activation/deactivation of the defrost mode (on/off).
If activated, this mode allows the heat pump to function at air temperatures as low as
-5°C.
Parameter
PRE-SET TEMPERATURE
ELEMENT
Factory default setting
76
52°C
65°C
DEACTIVATED
8h
DEACTIVATED
50°C
ACTIVATED
55°C
06:00
55°C
18:00